Do A Check On The Appliance; Maintenance Procedures; Remove The Door (Including Glass) - Bellfires Smart Bell 65 MF Installation And Maintenance Manual

Hide thumbs Also See for Smart Bell 65 MF:
Table of Contents

Advertisement

Maintenance
5 5 .1.2

Do a check on the appliance

1.
2.
3.
4.
5.
6.
7.
5.2

Maintenance procedures

5.2.1

Remove the door (including glass)

1.
2.
26
Do a check for leaks on the gas pipes and the gas pipe connections. Refer to
Make sure that the pilot light operates correctly. The pilot light must not show any
anomalies.
Make sure that the main burner operates correctly. The fire must not show any
anomalies.
Do a check of the gas supply pressure and the burner pressure.
a)
Use the inlet pressure tap and outlet pressure tap on the gas regulator block to
measure the supply pressure and the burner pressure.
b)
Measure the pressure when the appliance is off and when the appliance burns
on maximum. Refer to
Make sure that the ambient lighting operates correctly. Refer to the user manual.
If the convection fan is installed in the appliance, make sure it works correctly. Refer
to the user manual.
Do a check on the concentric flue system and the outlet construction. Make sure that
all the connections of the concentric flue system are secure.
Turn off the gas supply to the appliance before removing the door.
With the hook, pull the thin, metal spring strip on the top middle from the stud on the
door.
7
for the required supply pressure and burner pressure.
4.2.4
.
Smart Bell 65-55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart bell 55 mfSmart bell 55

Table of Contents