  • Page 1 P P reparation manual Box Gas Panorama 45/45 MF Serial number: Production date:...
  • Page 2 Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
  • Page 3: Table Of Contents

    Dimensions of the restriction plate.....................19 Available components for the concentric flue system......20 Appliance part list........................20 Bellfires - Muelink & Grol system Ø100 - Ø150................. 21 Poujoulat - DUOGAS system Ø100 - Ø150................25 Ontop - Metaloterm US system Ø100 - Ø150................28 Jeremias/STB - H-Twin system Ø100 - Ø150................32...
  • Page 4: About This Document

    • Preparation for installation This document refers to the Box Gas Panorama 45/45 MF as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance. Keep it in a safe place.
  • Page 5: Overview Of The Concentric Flue System

    Overview of the concentric flue system Overview of the concentric flue system The concentric flue system provides the appliance with combustion air and removes the flue gases from the appliance. The concentric flue system is made of these items: Item Description Concentric flue The concentric flue is a pipe with an inner pipe.
  • Page 6: Safety

    Only use items in the installation that are specified in this manual and the related documents. • Only use the following brands for the installation of the concentric flue system: Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system Jeremias/STB (STB = Schoorsteen...
  • Page 7: Requirements

    Requirements Requirements Requirements on the location • The floor must be sufficiently strong and stable, because of the weight of the appliance. • Make sure that you keep the minimum safety distances of the appliance to flammable and nonflammable materials. Refer to the installation and maintenance manual. •...
  • Page 8: Requirements On The Wall Outlet

    Requirements 4 4 .3.2 Requirements on the wall outlet Make sure that the outlet is installed at least 0.5 meter from: • The corner of a building • the edge of the roof • The roof overhang and rain gutter •...
  • Page 9: Requirements On The Concentric Flue System

    Requirements 4 4 .4 Requirements on the concentric flue system Caution: • Make sure that no flammable materials are located close to the flue system. The outer walls of the flue system can be 150 °C. • Make sure that the part of the concentric flue system, which goes up from the ceiling, is in a casing.
  • Page 10: Possibilities For A Concentric Flue System With A Roof Outlet

    Requirements 4 4 .4.1 Possibilities for a concentric flue system with a roof outlet Rigid concentric flue systems 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm...
  • Page 11 Requirements 14,15 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
  • Page 12 Requirements F F lexible concentric flue systems 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Roof outlet using an flexible Ø100 mm liner in an existing lined chimney. Box Gas Panorama 45/45...
  • Page 13 Requirements ≥45° 10/11/12/13 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
  • Page 14 Requirements 27,28,29 26,29 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) Ø100-Ø150 mm 2.0 - 4.0 m 30 mm 4.0 - 12.0 m 40 mm Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing unsound lined chimney.
  • Page 15 Requirements ≥45° 27,28,29 26,29 4,28,(100) Flue gas restriction plate width Concentric connection on the appliance is (min. - max.) (min. - max.) (min. - max.) Ø100-Ø150 mm 1.0 - 11.0 m 0 - 3.0 m 1.0 - 11.0 m Caution: Make sure that Y is at least 2 times larger than X.
  • Page 16: Possibilities For A Concentric Flue System With A Wall Outlet

    Requirements 4 4 .4.2 Possibilities for a concentric flue system with a wall outlet Install the wall outlet in the correct position as shown in the figure. The centre of the inner pipe must be positioned above the centre of the outer pipe. Rigid concentric flue systems 0.16 m 10/11/12/13...
  • Page 17: Technical Specification

    Technical specification Technical specification Dimensions Box Gas Panorama 45/45 Box Gas Panorama 45/45...
  • Page 18: Dimensions Box Gas Panorama 45/45 With Storage Module

    Technical specification 5 5 .2 Dimensions Box Gas Panorama 45/45 with Storage module Box Gas Panorama 45/45...
  • Page 19: Dimensions Box Gas Panorama 45/45 With Support Frame

    Technical specification 5 5 .3 Dimensions Box Gas Panorama 45/45 with Support frame Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Roof-mounted outlet Box Gas Panorama 45/45...
  • Page 20: Available Components For The Concentric Flue System

    European CE-norm for gas appliances and may therefore be used only with these systems. Table 1: Approved brands Manufacturer system Bellfires Muelink & Grol system Poujoulat DUOGAS system Ontop Metaloterm US system...
  • Page 21: Bellfires - Muelink & Grol System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .2 Bellfires - Muelink & Grol system Ø100 - Ø150 Bellfires Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Twin-wall balanced flue pipe. 302289 ● ● L= 500 mm.
  • Page 22 Available components for the concentric flue system Bellfires Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Twin-wall balanced flue el- 302298 ● ● bow 45°. Vertical (roof) termination kit, 302295 ● ● ● ●...
  • Page 23 Available components for the concentric flue system Bellfires Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Ceiling plate for transition 302189 Ø100 mm / Ø150 mm rigid - ● ● ● Ø100 mm (flex.).
  • Page 24 Available components for the concentric flue system Bellfires Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Vertical (roof) termination kit, 302307 L = 610 mm. Suitable for a ● ● ● ● flexible flue system.
  • Page 25: Poujoulat - Duogas System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .3 Poujoulat - DUOGAS system Ø100 - Ø150 Poujoulat Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Twin-wall balanced flue pipe, L= 250 mm. 34100403 Twin-wall balanced flue pipe. 34100404 ●...
  • Page 26 Available components for the concentric flue system Poujoulat Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Vertical (roof) termination kit, 34100654 ● ● L= 140 mm . Roof flashing, suitable for a 45150171 brick roof, with a roof pitch of ●...
  • Page 27 Available components for the concentric flue system Poujoulat Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Ceiling/wall plate with 37100442 spacers and ventilation ● ● grooves. Set of ceiling finishing plates / 37100425 Fire stops, suitable for a roof ●...
  • Page 28: Ontop - Metaloterm Us System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .4 Ontop - Metaloterm US system Ø100 - Ø150 Ontop Art./ Color (*) Application Fig. ORDER DESCRIPTION antr. rigid flex Adapter for Bellfires applian- USA 10 ces with Ø100-Ø150 mm ● ●...
  • Page 29 Available components for the concentric flue system Ontop Art./ Color (*) Application F F ig. ORDER DESCRIPTION antr. rigid flex Twin-wall balanced flue el- USB 15 10 ● ● bow 15°. Vertical (roof) termination kit, USDVC2 10 ● ● L= 375 mm. USSR 10 Storm collar Ø150 mm.
  • Page 30 Available components for the concentric flue system Ontop Art./ Color (*) Application F F ig. ORDER DESCRIPTION antr. rigid flex USAB 10 Cover band, screw-fastening. ● ● USMB 10 Wall strap, adjustable. ● ● USEB 10 Fitting bracket. ● ● Set of ceiling finishing plates / USCP 10 ●...
  • Page 31 Available components for the concentric flue system Ontop Art./ Color (*) Application F F ig. ORDER DESCRIPTION antr. rigid flex Locking band, screw-fasten- USKBS 10 ● ● ing. Concentric pipe with inspec- USI 10 ● ● tion panel, L= 250 mm. Concentric pipe with gauging USEM 10 ●...
  • Page 32: Jeremias/Stb - H-Twin System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .5 Jeremias/STB - H-Twin system Ø100 - Ø150 Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. ATWINL 13 Twin-wall balanced flue pipe. ● ● 100-150 L= 1000 mm. ATWINL 14 Twin-wall balanced flue pipe.
  • Page 33 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. ATWIN 17 Twin-wall balanced flue el- ● ● 100-150 bow 30°. ATWIN 18 Twin-wall balanced flue el- ● ●...
  • Page 34 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. ATWIN 92 Roof termination - short with ● ● ● 100-150 pipe, L = 300 mm, Vertical. Roof termination, with pipe, L ATWIN = 495 mm, Vertical, with roof 92pe...
  • Page 35 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Horizontal (wall) termination A681 kit, L= 495 mm (horizontally ● ● 100-150 adjustable), including one set of wall spacer plates. Concentric T-piece with H-TWIN 752 gauging orifice.
  • Page 36: Jeremias - Twin-Gas System Ø100 - Ø150

    Available components for the concentric flue system 6 6 .6 Jeremias - TWIN-GAS system Ø100 - Ø150 Jeremias Color (*) Application Fig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Bellfires Appliance connec- tion / Adapter Bellfires TWG1634 Ø100/150 mm → Jeremias ●...
  • Page 37 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Telescopic twin-wall balanced TWG50 flue pipe, L= min. 330 / max. ● ● 100-150 420 mm Including locking band.
  • Page 38 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Roof termination (vertical) L= TWG272 615 mm. Including locking ● ● 100-150 band. Roof flashing with a roof pitch TW53 150 of 5°...
  • Page 39 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Locking band, screw-fasten- TW45 150 ● ● ing (spare part). Silicone sealing ring for outer ALBI26 150 ● pipe (spare part).
  • Page 40 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Set of ceiling finishing plates / Fire stops with ventilation DA99VHL ● ● openings for a pitched roof : 0°...
  • Page 41 Available components for the concentric flue system Jeremias Color (*) Application F F ig. Art./ OR- DESCRIPTION antr. rigid flex DER NO. Base plate/Cover-under with TWG05 2x ½” gauging orifice, sealing ● ● 100-150 cap and condensate drain at the bottom. TWG07 Base plate / floor support.
  • Page 42 Available components for the concentric flue system 4 4 2 Box Gas Panorama 45/45...
  • Page 43 Available components for the concentric flue system Box Gas Panorama 45/45 4 4 3...
  • Page 44 Y Y our Bellfires dealer 001 - 29.08.2018 - 347718...

Table of Contents