3M -Matic 8000a Instructions And Parts List page 40

Adjustable case sealer with accuglide 3 taping heads
Hide thumbs Also See for 3M-Matic 8000a:
Table of Contents

Advertisement

12. Operation
12.9 Trouble Shooting Guide
PROBLEM
PROBLEM
After turning the ON/OFF
switch to the On position,
machine does not start
The magnetothermic protec-
tion
opens the main switch
Drive belts do not convey
boxes
Drive belts do not turn
3M-Matic
8000a-8000a3
Page 28
(continued)
CAUSE
CAUSE
The lockable emergency stop
button is pressed
Motor under stress
Thermal cut-out not at correct
amperage setting
Narrow boxes
Worn drive belts
Taping head applying spring
holder missing
Taping head applying spring
set too high
Worn or missing friction rings
Drive belt tension too low
Electrical disconnect
Motor not turning
CORRECTION
CORRECTION
Release the emergency stop
button
Check the electrical system
Check that the drive belts are
not blocked
Set the correct amperage
Check machine specifi cations
Boxes are narrower than
recommended, causing
slippage and premature belt
wear
Replace drive belts
Adjust the box height adjust-
ment with the crank
Reduce spring pressure
Replace friction rings
Adjust belt tension
Check power and electrical
plug
Evaluate problem and correct
(continued on next page)
NA - ENG
April 2016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3m-matic 8000a311600

Table of Contents