APRILIA RSV4 Factory Service Station Manual page 194

Hide thumbs Also See for RSV4 Factory:
Table of Contents

Advertisement

Electrical system
throttle body connector and control unit connector and check if there is cables continuity; if
there is no continuity, restore the cable harness. If there is continuity, with the throttle body
connector connected, check that the resistance, from the throttle control unit connector,
between PIN 3 and 15 is within 1 and 2.5 Ohm; if it is not, replace the throttle body; if it is,
check that the throttle body is not mechanically blocked: if blocked, solve the problem and
replace the body; if it is not, replace the control unit
DIAGNOSIS INSTRUMENT: LOGIC ERRORS
potentiometer 1 sensor, rear throttle position P0121
signal not valid
Error cause
Signal not within the expected value drawn according to the values of the intake pressure
Troubleshooting
Check the parameter of the Potentiometer 1 front Throttle (voltage) to get which signal the
control unit receives and to compare it to the Potentiometer 1 rear Throttle (voltage). Check
the throttle body connector as well as the control unit connector. Check that the resistance
of the cable between the throttle body connector (PIN 1) and the control unit (PIN48) is a
few tenths of an Ohm. If different, restore cable harness, if OK, replace the entire throttle
body
potentiometer 2 sensor, rear throttle position P0123
signal not valid
Error cause
Signal not within the expected value drawn according to the values of the intake pressure
Troubleshooting
Check the parameter of the Potentiometer 2 front Throttle (voltage) to get which signal the
control unit receives and to compare it to the Potentiometer 2 rear Throttle (voltage). Check
the throttle body connector as well as the control unit connector. Check that the resistance
of the cable between the throttle body connector (PIN 4) and the control unit (PIN50) is a
few tenths of an Ohm. If different, restore cable harness, if OK, replace the entire throttle
body
rear throttle position potentiometer P0124
incongruent signal
Error cause
ELE SYS - 194