RSV4 Factory
41. T-shaped bushing
42. TE M6x30 screw
TABLE J2 - EXHAUST VALVE ACTUATOR
Positioning and calibration Actuator - valve
Bowden cable (45) fitting procedure
•
Insert the cables with the set screws
closed in the following sequence:
1. Valve side closing cable (44) (univocal fit-
ting)
2. Actuator side closing cable (44)
3. Valve side opening cable (45) (univocal fit-
ting)
4. Actuator side opening cable (45)
•
Turn the closing cable set screw until
there is a distance of 1.9-2 mm
(0.0748-0.0787 in) between the me-
chanical endstop and the pulley.
•
Finally tighten the lock nut on the set
screw.
TABLE J3 - EXHAUST VALVE ACTUATOR
Positioning and calibration Actuator - valve
Bowden cable (45) fitting procedure
•
Turn the opening cable (43) set screw
until the cable tension is identical to the
closing cable (44).
•
Finally tighten the lock nut on the set
screw.
Electrical system