Electrical system
TABLE ZM
159. Clamp
160. Self-tapping 5x20 screw
TABLE ZN
The connectors (161) "ECU 1" (output "26") and
(162) "ECU 2" (output "25") must be connected to
their respective connectors on the 7SM control
unit, being very careful when inserting them. The
slides must move freely until the end of the stroke,
which helps with connector insertion: you must
hear the release of the retaining tang at the end of
the stroke.
161. "ECU 1" cable harness connector (output
"26")
162. "ECU 2" cable harness connector (output
"25")
163. Cable harness routing (output "25") under the
mounting
164. Cable harness routing (output "25") above the
mounting