Planet UMG-2000 User Manual page 143

Hide thumbs Also See for UMG-2000:
Table of Contents

Advertisement

Step2. To press the "SIP Trunk" to create SIP Trunk for registering with IPX-300.
Step3. To press the "LCR" to setup LCR settings.
Gateway Trunk Setting:
UMG-2000 can make the off-net call either via the external voice gateway. Before you can
make the successful call, you have to fill in gateway's IP address and SIP port.
In this case, we created 172.16.0.10 for FXO Gateway (VIP-480FO), and 172.16.0.20 for
GSM Gateway (VIP-281GS).
FXO Trunk Setting:
You also could determine use which FXO port for outgoing call via LCR function.
In this case, we define channel 1 of FXO module.
LCR Trunk Group Setting:
When want to make VoIP calls through the above Gateway Trunk, FXO channel or SIP
Trunk, the user can use this function to accomplish the 2_Stage dialing method.
In this case, we created the rule for outgoing call.
Prefix No.61: When dialing the number 61, it will hear the prompt for dialing desired
external number. Then this call will go through FXO channel 1.
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Umg-2100Umg-2200

Table of Contents