Serial Connection - SignaMax 065-1063FS Series User Manual

Rs-232/422/485 to 100basefx device server/managed media converter
Table of Contents

Advertisement

Signamax 065-1063FSx series RS-232/422/485 to 100Base/FX Device Server / Media Converter
3.7

Serial Connection

This Device Server / Managed Media Converter features DIP switches on the rear
panel that sets the unit to the correct type of cable configuration to support connection
with a RS-232 / 422 / 485 device.
Definition of DIP Switches
No
Dip description
1
ON: Console / OFF: Data
2
RS-232
3
RS-422 / 485 (4W)
4
RS-485 (2W)
5
NA
6
NA
7
TMR (Terminator)
For setting the control function of the serial port, see the table below:
NOTE:
1.
If using the console mode, turn DIP Switch 1 to the ON position. For data
communication from the serial device keep the switch in the OFF position. If the
switch is in the ON position, data communication will be blocked, and in the OFF
position, console port access will be blocked.
2.
For some RS-422/485 devices which may not be designed to provide a DB-9
connection, please check the pin definition to connect the devices.
3.
For the initial installation, you must use the console mode to setup the IP and
TCP port configuration with a RS-232 cable. Always use a cross-over cable; if
using a straight-through cable, you must use a "Null Modem" cable to use the
Telnet option.
DIP 1
Serial Connection
ON
RS-232 Console
OFF
Data Communication
8
Default
OFF
ON
OFF
OFF
OFF
OFF
OFF