BeaconMedaes 4107 9006 25 Installation, Operation And Maintenance Instructions page 29

Scroll laboratory air compressor system
Table of Contents

Advertisement

"Oil-Less" Scroll Laboratory Air
5.0 Maintenance
5.2.8 5 & 10 Hp Only Service Intervals
PART / KIT
QTY
NUMBER
5 Hp
1 per unit
4107 4018 81
10 Hp
1 per unit
4107 4018 82
* Intervals: Cleaning of the parts guiding the cooling air and replacement of the tipseals should be performed
during every service interval.
5.2.9 7.5 & 15 Hp Only Service Intervals
PART / KIT
QTY
NUMBER
7.5 Hp
1 per unit
4107 4000 56
15 Hp
1 per unit
4107 4000 58
** Strokes: Number of strokes valid with recommended purchased grease pump from
Grease Pump Kit 2903 0139 00 and Grease Cartridge 2892 6100 20
4107 9006 25.11
ACTION
Tip Seal Kit
Orbit bearing
Pincrank bearing rotor side
Cooling duct system
Rotor fi ns
Stator fi ns
ACTION
Tip Seal Kit
Orbit bearing
Pincrank bearing rotor side
Cooling duct system
Rotor fi ns
Stator fi ns
5-6
AT EACH 5,000 RUNNING HOURS OR
EVERY 2-YEARS
Replace
Regrease: 3.9 cm3
(6 strokes**)
Regrease: 2 cm3
(3 strokes**)
Clean
Clean
Clean
AT EACH 5,000 RUNNING HOURS OR
EVERY 2-YEARS
Replace
Regrease: 3.9 cm3
(6 strokes**)
Regrease: 2 cm3
(3 strokes**)
Clean
Clean
Clean

Advertisement