Function Setting - Waterco Electroheat ECO-V Installation And Operation Manual

Pool heat pump
Hide thumbs Also See for Electroheat ECO-V:
Table of Contents

Advertisement

41 I Pool Heat Pump

Function setting

Long press the mode key
Code
S01
Reserved
S02
Model selection
S03
Reserved
S04
Defrost mode
Defrost into temperature
S05
setting
Defrost exit temperature
S06
setting
S07
Defrost interval
S08
Defrost process time
Difference between
S09
defrost coil and external
environment
Water pump operation
S10
mode selection
Initial opening of auxiliary
S11
valve
Fixed frequency
S12
operation
Fixed frequency
S13
frequency setting
Enthalpy valve opening
S14
ambient temperature
Main valve electronic
S15
expansion valve
adjustment
Main electronic
S16
expansion valve pulse
opening setting
+ up key
Type
Defaults
for 3 seconds to enter.
Settable range
1
0-1
0 single cold, 1
2
cold and warm, 2
single hot
1
1-6 Reserved
0
0/1 Reserved
-4˚C
0 - -30˚C
15˚C
2 - 20˚C
40min
25-200min
12min
2 - 20min
6˚C
0 - 10˚C
0 long open; 1
0
cycle; 2 to warm
stop
80
0 ~ 520
0 automatic
operation; 1
0
fixed frequency
operation
60
0 - 120HZ
7˚C
0 - 15˚C
0 automatic
0
operation; 1 fixed
pulse operation
120
0 - 520
Remarks