IMPORTANT SAFETY INSTRUCTIONS

When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
! WARNING: Disconnect all AC power during installation and servicing.
! WARNING: In order to avoid the possibility of hyperthermia (heat stress) occurring it is
recommended the average temperature of the spa - pool water does not exceed 40°C
/ 104°F.
! WARNING: The pool heat pump is not intended for use by persons (including children)
with reduced physical sensory or mental capabilities, or lack of experience and
knowledge, unless they have been provided supervision or instruction concerning use
of the appliance by a person responsible for their safety. Children should be supervised
to ensure they do not play with the appliance.
• In certain situations unexpected start up may occur when the appliance is in automatic
mode.
• The installer should assess the risk associated with unexpected start-up of this device
which, in any circumstance should have no hazardous effect.
• The pool heat pump is not meant to provide safety protection for other devices.
• The pool heat pump should be deactivated if the pool or spa has been drained.
• Waterco pool heat pumps must be installed by a suitably qualified person in accordance
with current Regulatory Standards, the applicable Wiring Rules (AS3000) and local
statutory authority regulations.
• Parts containing live parts, except parts supplied with safety extra-low voltage not
exceeding 12V, must be inaccessible to a person in the spa – pool.
• Parts incorporating electrical components, except remote control devices, must be
located or fixed so that they cannot fall into the spa – pool.
• The appliance should be supplied through a residual current device (RCD) having a
rated residual operating current not exceeding 30mA.
• An Earth terminal is located inside the wiring enclosure. To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the
electric supply service panel with a continuous copper wire as sized to comply with
current Standards and local statutory authorities in relation to the circuit conductors
supplying the equipment.
• A cable connector is provided on this unit to connect a suitably sized copper conductor
between this unit and any metal equipment, metal enclosures of electrical equipment,
metal water pipe, or conduit within 1.5m of the unit via equipotential bonding.
SAVE THESE INSTRUCTIONS.