Waterco Ultra User And Care Manual Manual

Waterco Ultra User And Care Manual Manual

Pool heat pump

Advertisement

AUSTRALIA
NSW - Sydney (HEAD OFFICE)
Tel: +61 2 9898 8686
VIC/ TAS - Melbourne
Tel: +61 3 9764 1211
WA - Perth
Tel: +61 8 9273 1900
QLD – Brisbane
Tel: +61 7 3299 9900
SA/ NT - Adelaide
Tel: +61 8 8244 6000
NEW ZEALAND
CANADA / NORTH-EAST USA
Waterco (NZ) Limited
Waterco Canada Inc
Auckland, New Zealand
Quebec, Canada
Tel: +64 9 525 7570
Tel: 1 888 796 6002
USA
EUROPE
Waterco USA Inc
Waterco (Europe) Limited
Augusta, USA
Tel: +17067937291
Sittingbourne, Kent. UK
Tel: +44(0) 1795 521 733
+18002477291
Website / Internet :
www.waterco.com
This web site address will enable you to select the appropriate country website.
Ce site web vous permettra de choisir le pays avec lequel vous devrez communiquer.
Waterco Limited ABN 62 002 070 733
(ZZM1331) 04/2012
CHINA
Waterco (C) Limited
Guangzhou, China
Tel: +8620 3222 2180
MALAYSIA
Waterco (Far East) Sdn. Bhd.
Selangor, Malaysia
Tel: +60 3 6145 6000
WATERCO POOL HEAT PUMP
WATERCO THERMOPOMPE CHAUFFE-PISCINE
User and
Care Guide Manual
Guide d'utilisation
et d'entretien
This equipment must be installed and serviced by a qualified technician. Improper
installation can create electrical hazards which could result in property damage,
serious injury or death. Improper installation will void the warranty.
Cet équipement doit être installé et réparé par un technicien qualifié. Une mauvaise
installation peut entraîner des risques électriques qui pourraient provoquer des
dommages, des blessures graves ou la mort. Une installation inadéquate annulera
la garantie.
Notice to Installer / Avis à l'installateur
This manual contains important information about the installation, operation and safe
use of this product. Once the product has been installed, this manual must be given
to the owner/operator of this equipment.
Ce manuel contient des informations importantes sur l'installation, l'exploitation et
l'utilisation sécuritaire de ce produit. Une fois que le produit a été installé, ce manuel
doit être remis à l'acheteur et/ou utilisateur de cet équipement.
www.waterco.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Waterco Ultra

  • Page 1 This web site address will enable you to select the appropriate country website. doit être remis à l’acheteur et/ou utilisateur de cet équipement. Ce site web vous permettra de choisir le pays avec lequel vous devrez communiquer. Waterco Limited ABN 62 002 070 733 www.waterco.com (ZZM1331) 04/2012...
  • Page 2: Table Of Contents

    During certain periods, it may be necessary to operate your pool heat pump continuously. Nothing Is Working but the Electronic Breaker Size ________________________ However, this should not be of concern as your Waterco pool heat pump can heat up your pool Control Displays Digits or a Code _________ Electrical Wire Size ___________________ 80% more economically than the fossil fuel heating or heaters with electric elements.
  • Page 3: General Safety Instructions

    This high concentration of chemicals should be avoided. To find detailed product information, the location of the nearest dealer or to register your Water quality standards that must be strictly adhered to*: pool heat pump, please visit our website www.waterco.com and select your location. DESCRIPTION NORMAL RANGE*...
  • Page 4: Installation Instructions

    Pool Heat Pump | Pg 06 GENERAL SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS DO NOT DEPRIVE YOUR POOL HEAT PUMP OF WATER FLOW FOR MORE THAN 24 Location HOURS WITHOUT DRAINING IT. Make sure you leave the bypass valves as shown in Figure 1.
  • Page 5: Water Piping

    If the pool heat pump shuts down automatically no further action is required. If the pool heat pump continues to run, you will need to have a qualified technician adjust the water pressure switch (not under warranty). For further information, please contact Waterco.
  • Page 6: Bonding

    Warranty will be voided if be operated and must be switched off. system is not properly bonded. For Ultra and Reversible (XLR) units, they will automatically stop without human CAUTION: It is recommended when using automatic chlorinators, to ensure that they intervention.
  • Page 7: Pool Solar Blanket

    Pool Heat Pump | Pg 12 OPERATION OF YOUR POOL HEAT PUMP OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket To Start the Pool Heat Pump A pool solar blanket should be used whenever possible. Blankets minimize heat loss and Press the button ON/OFF on the electronic control to start the pool heat pump.
  • Page 8: Specific Functioning Of Your Reversible

    Pool Heat Pump | Pg 14 Functioning of your Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP and Reversible (XLR) Electronic Control with Diagnostics Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe (sensor).
  • Page 9: Installation With A Remote Control

    The integrity and performance of your pool heat pump and its components are protected by internal safety controls. In normal use, your Waterco unit should never reach the thermal Note: This option could be install with all our product by following our protection level.
  • Page 10: Maintenance Of Your Pool Heat Pump

    65 °F (18 °C) damage the pool heat pump and will void the warranty. If you made the purchase of equipment not included with the Waterco pool heat pump, 1. Turn the pool heat pump OFF; make sure that the equipment was properly installed. If the problem is the installation of the 2.
  • Page 11: Nothing Is Working But The Electronic Control Displays Digits Or A Code

    If you made the purchase of an automation system (or another equipment not included with “Compressor Starts and Stops”. the Waterco pool heat pump), make sure that the equipment was properly installed. If the problem is the installation of the other equipment, Waterco warranty will not apply and you Compressor Starts and Stops will pay the service call fees.
  • Page 12: Pool Heat Pump Has Ice Formed On The Evaporator Coil

    4. Waterco recommends the use of a solar cover to retain heat of pool water. Pools without 6. When the unit has been switched ON, ensure the fan motor is working (fan blades will be covers lose 2 to 3 times more heat than pools with solar covers.
  • Page 13: Analysis Chart

    Waterco during the service call, the owner will have to pay for the service call fees since it will not be covered by the warranty.
  • Page 14: Service Analyser Codes

    For Ultra or Reversible (XLR) Model: If the unit performs 4 consecutive Check swimming pool and pool pump skimmer baskets and the drain at cycles (heating and defrost) within 1 hour, the unit goes into protection mode the bottom of the pool for obstructions;...
  • Page 15 Make sure the vacuum robot is disconnected so the water flows freely; must be above If you have a two speeds pool pump, make sure that it is set at the Ultra 32 °F (0 °C) 50 °F (10 °C) highest speed.
  • Page 16: Warranty

    Adjust or re-establish water flow to the pool heat pump. If in home service is not available, the product will be repaired or replaced at Waterco When a service call with no manufacturing problem has been detected, on site, by the discretion by the nearest authorized service provider.