Waterco Electroheat ECO-V 17kW Installation And Operation Manual

Waterco Electroheat ECO-V 17kW Installation And Operation Manual

Pool heat pump
Table of Contents

Advertisement

OFFICES – AUSTRALIA
OFFICES – OVERSEAS
NSW - SydNey
WATerCO (eurOPe) lIMITed
(HeAd OFFICe)
Sittingbourne, Kent, uK
Tel
: +61 2 9898 8600
Tel
: +44 (0) 1795 521 733
VIC/TAS - MelbOurNe
WATerCO uSA
Tel
: +61 3 9764 1211
Augusta, uSA
Tel
: +1 706 793 7291
WA - PerTH
Tel
: +61 8 9273 1900
WATerCO CANAdA
boucherville, Quebec, Canada
Qld - brISbANe
Tel
: +1 450 748 1421
Tel
: +61 7 3299 9900
WATerCO (NZ) lIMITed
SA/NT - AdelAIde
Auckland, New Zealand
Tel
: +61 8 8244 6000
Tel
: +64 9 525 7570
ACT dISTrIbuTOr
Tel
: +61 2 6280 6476
www.waterco.com.au
This web site address will enable you to select the appropriate country website.
Waterco Limited ABN 62 002 070 733
Waterco Limited ABN 62 002 070 733
(ZZM1818) 11/2019
WATerCO (C) lIMITed
Guangzhou, China
Tel
: +8620 3222 2180
WATerCO (FAr eAST) SdN bHd
Selangor, Malaysia
Tel
: +60 3 6145 6000
PT WATerCO INdONeSIA
Jakarta, Indonesia
Tel
: +62 21 4585 1481
WATerCO SINGAPOre INTl PTe lTd
Nehsons building, Singapore
Tel
:
+65 6344 2378
WATERCO POOL HEAT PUMP
WATERCO THERMOPOMPE CHAUFFE-PISCINE
Installation and
Operation Manual
Manuel d'installation
et d'utilisation
This equipment must be installed and serviced by a qualified technician.
!
WARNING
Improper installation can create electrical hazards which could result in property
damage, serious injury or death. Improper installation will void the warranty.
Cet équipement doit être installé st réparé par un technicien qualiflié.
une mauvaise installation peut entraîner des risques électriques qui pourraient
provoquer des dommages, des blessures graves ou la mort. une installation
inadéquate annulera la garantie.
Notice to Installer / Avis à l'installateur
This manual contains important information about the installation, operation and
safe use of this product. Once the product has been installed this manual must
be given to the owner/operator of this equipment.
Ce manual contient des informations importantes sur l'installation, I'exploitation
et l'utilisation sécuritaire de ce produit. une fois que le produit a été installé, ce
manuel doit être remis à l'acheteur et/ou utilisateur de cet équipement.
www.waterco.com.au

Advertisement

Table of Contents
loading

Summary of Contents for Waterco Electroheat ECO-V 17kW

  • Page 1 This web site address will enable you to select the appropriate country website. manuel doit être remis à l’acheteur et/ou utilisateur de cet équipement. www.waterco.com.au Waterco Limited ABN 62 002 070 733 Waterco Limited ABN 62 002 070 733 (ZZM1818) 11/2019...
  • Page 2: Table Of Contents

    • The pool heat pump should be deactivated if the pool or spa has been drained. refrigerant Charge Indicator Gauge Pool Heat Pump Has Ice Formed On The • Waterco pool heat pumps must be installed by a suitably qualified person in accordance Performance Specifications evaporator Coil...
  • Page 3: A Note To You

    Model Number _________________________________________________________________ as your Waterco pool heat pump can heat up your pool approximately 80% more economically than the fossil fuel heating or heaters with electric elements. Waterco...
  • Page 4: Installation Instructions

    05 I Pool Heat Pump Pool Heat Pump I 06 INSTALLATION INSTRUCTIONS Installation Clearances Air is pulled through the evaporator coil and discharged from the top grill. Clearances Location must be allowed in front and around the unit for unrestricted air discharge and service access.
  • Page 5: Water Piping

    Waterco offer prefabricated water bypass kits to fit their heat pump domestic range. Ask your local Waterco sales office for details.
  • Page 6: Electrical

    On some older pools, this substructure bond wire may not exist. In these cases, a 3-4 Waterco recommend connecting the unit to an isolating switch to allow ease of foot solid copper rod must be driven into the ground near equipment; all electric and service and maintenance.
  • Page 7: Remote Control Connections

    This high concentration of chemicals should be avoided. 2. unbolt and remove the front access panel. 3. Open control box cover. Water quality standards that must be strictly adhered to*: 4. To connect a 2-Wire Control such as Waterco Aquamaster™: DESCRIPTION NORMAL RANGE* VERIFY...
  • Page 8: Performance Specifications

    R410A R410A R410A Waterco eCO-V pool heat pumps do not require the water by pass valves adjusted Display to cope with cooler water temperatures. In the event of low water temperatures, the eCO - V inverter pool heat pumps increase the operating frequency of the compressor...
  • Page 9: Pool Heat Pump Running Time

    15 I Pool Heat Pump Pool Heat Pump I 16 Pool Heat Pump Running Time INVERTER POOL HEAT PUMP CONTROLLER Most units should be sized to operate during the pool filtering cycle time of 8-12 This controller applies to dC inverter air source pool heat pumps, for heating. daytime hours daily during warmer months and up to 8 hours daily during the daytime in winter months.
  • Page 10: Controller Functions

    17 I Pool Heat Pump Pool Heat Pump I 18 Function Descriptions Controller Functions 1. When power to the unit is switched on the controller display will illuminate. 2. use the uP and dOWN arrow buttons on the keypad to adjust. Adjustable functions: For users, the current temperature, flash, “...
  • Page 11: Maintenance Of Your Pool Heat Pump

    MAINTENANCE OF YOUR POOL HEAT PUMP Winterising Procedure Waterco pool heat pumps have been specifically engineered to give you years of satisfaction and enjoyment in the pool. If the pool heat pump is stored in a place where the temperature drops below the freezing point of 0˚C / 32°F;...
  • Page 12: General Safety Instructions

    Please ensure the unit and any related equipment is installed in accordance with the HOURS WITHOUT DRAINING IT. Make sure you leave the bypass valves as shown installation manual. If not, the Waterco warranty will not apply and the customer may in Figure 1.
  • Page 13: Fan Blades Turn, But Compressor Is Not Functioning

    2. Open the bypass valve. (refer to drawing on page 5) 3. Close the IN and OUT water valves on the unit. 4. Waterco recommend the use of a solar cover to retain heat in pool water. Pools 4. restart the pool pump. The pool heat pump must remain OFF.
  • Page 14: Circuit Breaker Trips

    If you have purchased a remote control (or other equipment), ensure the equipment is correctly installed. If an operational issue originates from incorrect operation or installation of this equipment, Waterco’s warranty will not apply and you will have to pay the cost of the service call.
  • Page 15: Electric Circuit Drawing

    27 I Pool Heat Pump Pool Heat Pump I 28 Electric Circuit Drawing electroheat eCO V 17kW; electroheat eCO V 21kW electroheat eCO V 25kW...
  • Page 16: Service Parameters Tables

    29 I Pool Heat Pump Pool Heat Pump I 30 Service Parameters Tables error code table Press and hold the “ ” button for 5s to enter the status query: Code description Query Code Meaning display range er03 Flow side error Inlet water temperature -20~99°C er04...
  • Page 17: Parameter Number And Description Table

    31 I Pool Heat Pump Pool Heat Pump I 32 Parameter Number and Description Table Press and hold the “Set” key for 5s to enter the password setting interface; enter “0814” to enter the parameter query interface: Setting Setting Parameter Name Adjustment Range Initial Value Parameter Name Adjustment Range Initial Value...
  • Page 18: Warranty

    Proof of purchase G. Parts and pool heat pump transportation. must be forwarded to Waterco and they will inform you of the applicable warranty. H. Fees charged for excessive time to repair your pool heat pump due to incorrect or...

This manual is also suitable for:

Electroheat eco-v 21kwElectroheat eco-v 25kwEco-v

Table of Contents