Service Parameters Tables - Waterco Electroheat ECO-V Installation And Operation Manual

Pool heat pump
Hide thumbs Also See for Electroheat ECO-V:
Table of Contents

Advertisement

Service Parameters Tables

Error code table
Code
Description
E03
Flow failure
E04
Anti-freeze protection
E05
High pressure protection
E06
Low pressure protection
E09
Connection failure between control mainProgram board and controller
E10
Connection failure between driver and mainProgram board
E11
After throttle temp sensor failure
E12
Exhaust temperature over
E15
Water inlet sensor failure
E16
Outside coil sensor failure
E18
Exhaust sensor failure
E20
Driver module protection
E21
Ambient temperature failure
E22
Vast temperature variations between inlet and outlet
E23
Water outlet temperature lower in Cooling Mode
E27
Water outlet sensor failure
E29
Suction pipe sensor failure
E30
Protection against low outdoor ambient temperature
E31
Overload protection of auxiliary electric heating
E32
Water outlet temperature over in Heat Mode
E33
Outside coil temperature over in Cooling Mode
E34
Compressor drive failure
E35
Compressor current over
E36
Compressor output failure
E37
IPM current failure
E38
Heat sink temperature too high
E39
Power overload shutdown (PFC failure)
E40
DC voltage over
E41
DC voltage lower
E42
Inside coil sensor failure
E43
AC voltage lower
E44
AC current over
E45
Driver E2 failure
E46
DC FAN failure
E47
AC voltage over
Pool Heat Pump I 38