Summary of Contents for Waterco Electroheat SubZero
Page 1
Improper installation will void the warranty. Notice to Installer This manual contains important information about the installation, operation and safe use of this product. Once the product has been installed this manual must be given to the owner/ operator of this equipment. www.waterco.com...
Table of A NOTE TO YOU ----------------------------------------------------- 01 SubZero ------------------------------------------------------------ 01 GENERAL SAFETY INSTRUCTIONS -------------------------- 02 INSTALLATION INSTRUCTIONS ------------------------------- 03 Location of SubZero -------------------------------------------- 03 OPERATION OF YOUR POOL HEATER ---------------------- 04 Operation of Multifunction Electronic Control Panel ---- 04 To start-up the unit ---------------------------------------------- 04 To stop the unit --------------------------------------------------- 04 To raise or lower desired water temperature ------------- 04...
SubZero (Technical Features) Our Waterco SubZero Heatpump was specifically developed to heat water through the use of ambient air to a temperature lower than standard models. The defrost is carried out by reversing the refrigeration circuit, thereby injecting hot refrigerant into the evaporator. It is possible to quickly defrost the evaporator even when the temperature in the air is closed to freezing point.
GENERAL SAFETY INSTRUCTIONS WARNING To ensure your safety and the adequate functioning of your heat pump, all electrical work should be performed by a fully qualified and licensed electrician in accordance with local electrical codes. An adequate circuit breaker and copper wiring must be used. Refer to the electrical installation diagram found on the inside of the access panel.
I pg 03 Heat Pump Swimming Pool Heaters INSTALLATION INSTRUCTIONS Location of SubZero The location of the pool heater is very important in keeping installation costs to a minimum, while providing for maximum efficiency of operation as well as allowing adequate service and maintenance access.
OPERATION OF YOUR POOL HEATER Operation of Multi-Function Electronic Control Panel The display of the control panel is factory set to show pool water temperature in degrees FAHRENHEIT. See “To select temperature in °C or °F” section in the general user handbook. Touch Pad Description •...
I pg 05 Heat Pump Swimming Pool Heaters Defrost Cycle SubZero The interval time between the defrost cycle depends on the temperature of the ambient air and of the humidity. During the defrost cycle, the ventilator stops functioning and the hot refrigerant is injected into the evaporator in order to melt the frost.
Winterizing If the unit is stored in a place where the temperature drops below the freezing point of 0°C, it is mandatory that the water accumulated in the unit be drained completely before freezing weather prevails. The water piping MUST be disconnected to drain the heat exchanger in preparation for winter.
I pg 07 Heat Pump Swimming Pool Heaters Service Analyser Codes Most problems will be detected by the service analyser and a code will be displayed on the digital display of your heater. DISPLAY MEANING OF CODE The desired programmed temperature point is lower than 15°C. LP &...
Page 10
SA/ NT - Adelaide Auckland, New Zealand Singapora Tel : +61 8 8244 6000 Tel : +65 6344 2378 Tel : +64 9 525 7570 ACT Distributor Tel : +61 2 6280 6476 Waterco Limited ABN 62 002 070 733 (ZZM1332) 03/2010...