Service Parameters Tables - Waterco Electroheat ECO-V 17kW Installation And Operation Manual

Pool heat pump
Table of Contents

Advertisement

29 I Pool Heat Pump

Service Parameters Tables

Press and hold the "
" button for 5s to enter the status query:
Query Code
Meaning
01
Inlet water temperature
02
Outlet water temperature
03
Ambient temperature
04
exhaust temperature
05
return air temperature
06
Outer coil temperature
07
Inner coil temperature
08
Main expansion valve opening
09
enthalpy increase expansion valve opening
10
Press current
11
Heat sink temperature
12
dC bus voltage
13
Press actual frequency
display range
-20~99°C
-20~99°C
-20~99°C
0~125°C
-20~99°C
-20~99°C
-20~99°C
Actual value/10
Actual value/10
Actual value/10
error code table
Code
description
er03
Flow side error
er04
Freeze in piping in winter
er05
High pressure switch error
er06
low pressure switch error
er09
Communication failure
er10
PCb error
er11
reserve
er12
High discharge temp error
er15
Water inlet probe error
er16
defrost probe error
er18
discharge probe error
er20
PCb abnormal error
er21
Ambient probe error
er23
lower water outlet temp error in cooling mode
er27
Water outlet probe error
er29
Suction temp error
er32
Higher water outlet temp error in heating mode
er35
Compressor overload current error
er43
Piping probe error
Pool Heat Pump I 30