IndraControl VEP 30.6, VEP 40.6,
VEP 50.6 Embedded Terminals
①
VESA attachment with four M4 threaded bolts (75 mm × 75 mm)
②
Cable bushings, appropriate for ready-made cables
Fig. 10-8: Position of VESA fastening screws and cable bushings
10.4.3 VESA support arm for the VEP 30.6
The operator terminals can be attached to a standardized VESA support arm
provided by different manufacturers.
10.5 Electric connection
DANGER
The 24 V DC input voltage must comply with the requirements of the "safe sepa-
ration"!
Plug and remove the plug connection only if there is no voltage!
NOTICE
Use only shielded cables and metallic, conductive connector or coupling hous-
ings with large-area shield support.
Interfering AC voltage components - such as the ones resulting from an uncon-
trolled three-phase bridge circuit without smoothing and with a ripple factor of
5 % (see DIN 40110/10.75, section 1.2) - are allowed.
Mounting, demounting and electric installation
Lethal danger without safe separation!
Malfunctions due to insufficient shielding!