HOW TO INSTALL
安裝方法
Connecting power cord
5
電源線的 連接
To avoid electric shock or fire, do not remove the
PCB cover.
安裝和使用時禁止拆卸電路板蓋板,否則可能會導致觸
電或起火。
Please select 60227 IEC 53(RVV) ordinary polyvinyl
chloride sheathed cord. Nominal cross-sectional
area of conductors is 3×1.5 mm².
電源線請選用60227 IEC 53(RVV)型軟線
導線的截面積為3×1.5 mm²。
For the stripping length, please prepare
according to the wiring sketch (refer to figure 1).
If the stripping length is too long, it may cause
short circuit.
剝線 長度 ,請按照 剝線 示意圖(右圖1)進 行剝 線, 如 剝線
過長 ,可 能會導致 產品 短路。
Do not damage the sheath of the power cord,
otherwise an electric shock or short circuit may
be caused .
電源 線的 絕緣膠不 能破 損,否則 可能 會 導致觸電或 短 路。
Strand the core wire together after stripping,
then insert them into about 8 mm deep position
of the terminal block, ensuring that the part is
under the spring slice, and no copper core cord is
exposed outside. Make sure that the copper core
cords are fixed by screws reliably (the
recommended screw fixing torque is 0.49 N m)
(See Figure 2). Otherwise an electric shock may
be caused.
先將剝線後 分散 的銅芯線 絞合 在一起, 然後 伸入到端子
台約8 mm深,並 確 保其在彈簧 片 的下方,切 勿 出現銅
線外露現象 。螺
鎖緊扭 矩為0.49 N m),否則可能 會 導致觸電。
(右圖2)
5 -1
Open the cord cover.
(1)Remove the screw on the cord cover.
(2)Open the cord cover.
(3)Lift the terminal cover(Do not remove
the terminal cover).
打開接線蓋板
(1)取 下 接 線 蓋 板 上的 螺絲 。
(2)打 開 接 線 蓋 板 。
(3)掀 起 端 子 保 護 蓋 ( 請不 要拆 下此 保護 蓋) 。
WARNING
警告
擰緊後 ,請 確保銅線 不易 鬆脫(建議
.
Conductor
電源線
Power cord
Insulation
.
Terminal cover
(Do not remove
this cover)
端子保護蓋
(請不要拆下
此保護蓋)
Cord cover
接線蓋板
Wiring sketch
剝線示意圖
銅芯線
Earth
接地引線
44±1
電源線
Unit:mm
單位:mm
Figure 1
圖1
Terminal cutaway view
接線柱剝面圖
Spring slice
彈簧片
Conductor
銅芯線
絕緣膠
Unit:mm
單位:mm
Figure 2
圖2
PCBcover
電路板蓋板
(3)
(1)
(2)
Self-tapping
screws 4 x 8
自攻螺絲
4 x 8
9