HOW TO INSTALL
安裝方法
5 -2
Loosen the screws of the cord clip.
將固定電源線線夾的螺絲鬆脫。
5 -3
Loosen the screws of the pillar terminal , insert the
power cord(not supplied)connected to the fixed
wiring which in the house into the pillar terminal ,
tighten the screw.
鬆開接線柱上的螺絲,將接入室內固定線路的電源線
(用戶自購)插入接線柱,擰緊接線柱螺絲。
5 -4
Fix the power cord with the cord clip.
(The cord clip must pin the insulation
sheath of power cord.)
用 線夾 將 電 源 線 固定。
(線 夾 必 須 壓 住 電 源 線 絕緣 護套)
When covering the terminal cover, be sure not to suppress
the earth wire, otherwise it may damage the earth wire.
蓋端子保護蓋時,請注意不要壓到地線,否則可能會壓傷地線。
5 -5
Fix the cord cover by the screws which
removed by step
5 -1
用步驟
拆下的螺絲
6
Push the main body upward into the ceiling board
and wooden frame by closely leaning against the
adapter, clip the clipping position of the main body
into the locating slot of the adapter (otherwise,
may have air leakage), and fix the main body with
six 4 x 30 self- tapping screws.
將機體緊靠出風口接頭往上推入天花板與木框,
並使機體上卡位卡入出風口接頭定位槽中
4x30
用 顆
6
的自攻螺絲將機體牢固地固定
Notice
提示事 項
Please be careful not to pinch the cord, when push
upward the main body.
推入
機 體
請 注 意 不 要夾 傷線 。
10
CAUTION
注意
.
5 -1
將接線蓋板重新固定。
(否則漏風),
Screws
Terminal
接線柱
Earth
wire
地線
Cord clip
線夾
Terminal cover
端子保護蓋
Screws
螺絲
Cord clip
線夾
Locating slot of the adapter
出風口接頭定位槽
螺絲
Clipping position
of the main body
機體卡位
Self-tapping
screws
4 x 30 (6 pcs)
自攻螺絲
4x30(6 )