MIDI System Exclusive Format
8: d (Parameter ID MSB)
9: e (Parameter value byte 0 (LSB)) - bits 0...6 of parameter value
10: f (Parameter value byte 1) - bits 7...13 of parameter value
11: g (Parameter value byte 2) - bits 14...20 of parameter value
12: h (Parameter value byte 3 (MSB)) - bits 21...23 of parameter value
13: 0xf7 (EOX end of SysEx message)
Determining the Parameter ID and value range for a specific parameter
To determine the parameter ID and value range for a particular Control Panel
knob, fader, button, or menu:
1.
2.
3.
This will generate SysEx data, which will be recorded by the sequencer.
4.
Maximum SysEx value
The maximum SysEx value for OASYS PCI is 8388607.
140
Enable SysEx transmission in OASYS PCI.
Start recording in your sequencer.
Move the Control Panel parameter.
Examine the data recorded into the sequencer.