Handle Housing; Special Servicing Tools, Servicing Aids; Removing Right Handle Housing; Removing The Blower Tube - Stihl BGA 86 Service Manual

Hide thumbs Also See for BGA 86:
Table of Contents

Advertisement

6

Handle Housing

14
13
8
4x16 (1 Nm / 9 lbf. in.)
10
9
8
4x16 (1 Nm / 9 lbf. in.)
6.1

Special Servicing Tools, Servicing Aids

Socket, T27 – 0812 542 2104
Torque wrench – 5910 890 0302
Screwdriver, T27x200 – 5910 890 2415
6.2

Removing Right Handle Housing

Preparations, @ 2.4.
N
Take out the screws (8).
N
Carefully lift away the right handle housing (11) –
N
controls and springs may pop out.
Locate the locking tabs inside the handle housing
N
(11) and push off the cover (10).
Lift the handle molding (9) slightly at the locking tabs
N
and take it away.
Remove the soundproofing (7).
N
6.3

Removing the Blower Tube

Remove right handle housing (11), @ 6.2.
N
Lift the blower tube (5) and nozzle (6) slightly and pull
N
them away from the blower (12).
Remove the nozzle (6) from the blower tube (5).
N
BGA 86
12
11
4
5
7
8
4x16 (1 Nm / 9 lbf. in.)
6.4

Removing the Blower

Preparations, ExternalLink: Preparations for repair.
N
Remove right handle housing, @ 6.2.
N
Remove the blower tube, @ 6.3.
N
15
16
13
12
Pull blade terminals of yellow wire (15), blue wire (16
N
an red wire (17) out of the receptacles.
Remove blower (12) with inlet cone (13).
N
Remove the inlet cone, @ 6.5.
N
1
2
3
6
17
9

Advertisement