15
16
13
12
Position blower (12) with inlet cone (13) on the left
N
handle housing.
Insert blade terminal of yellow wire (15) in the yellow
N
receptacle (YE).
Insert blade terminal of blue wire (16) in the blue
N
receptacle (BU).
Insert blade terminal of red wire (17) in the red
N
receptacle (RD).
Install the blower tube, @ 6.9.
N
12
Place the blower (12) with blower tube (5, 6) in the
N
guides (arrows) on the left handle housing.
Check position of motor wires. The wires must be
N
under the guide lugs (18).
Install right handle housing, @ 6.11.
N
BGA 86
6.11
17
N
N
N
18
5
N
N
N

Installing the Right Handle Housing

10
9
Push the cover (10) into the guides on the handle
housing (11) until the locking tabs (arrows) snap into
place.
Push the handle molding (9) against the handle
housing (11) until the locking tabs (arrows) snap into
place.
Fit the soundproofing (7) so that its cutouts engage
the tabs on the handle housing (11).
11
Fit the right handle housing (11) and check that no
wires are pinched. The motor wires must be under the
guide lugs (18).
Insert and tighten down the screws (8) firmly.
Check operation of controls, @ 7.9.
11
18
11

Advertisement