3
Troubleshooting
The following tables are intended to identify problems and remedy malfunctions. Always start troubleshooting at line 1 of
the table and work through the questions one by one.
3.1
Machine does not run or only hums
Check the following
1.
Battery - charged, properly installed,
not damaged?
2.
LEDs glow or flash red?
3.
3 LEDs flash red
4.
4 LEDs flash red
5.
3 LEDs glow continuously red:
6.
1 LED glows continuously red:
7.
Machine damaged?
Dirty contacts in battery
compartment?
8.
Check electrical components for dam-
age and correct function with ADG 2 –
replace as necessary, see @ 5
Does power tool now operate?
9.
Does power tool now operate?
4
Yes
Go to step 2.
Go to step 3.
Fault in machine
Test battery with ADG 2, see @ 5
Go to step 7.
Malfunction in battery
Test battery with ADG 1, see @ 4
Go to step 9.
Power tool too hot
Allow machine to cool down.
Go to step 9.
Battery too hot / cold
Allow battery to cool down / warm up.
Go to step 9.
Replace damaged parts.
Clean contacts in battery
compartment.
Go to step 9.
Repair completed.
Repair completed.
No
Charge / install properly / replace
battery
Go to step 9.
Go to step 7.
Go to step 4.
Go to step 5.
Go to step 6.
Go to step 2.
Go to step 8.
Go to step 1.
Go to step 1.
BGA 86