Hide thumbs Also See for TW205-206:
Table of Contents
  • Instrucciones de Instalación
  • Especificaciones
  • Instalación
  • Notas de Aplicación
  • Installation
  • Notes de Fonctionnement
  • Conformité Fcc

Advertisement

Available languages

Available languages

Quick Links

CAUTION
!
• Use copper wire only, insulate or wire nut all unused leads.
• Care should be used to avoid electrostatic discharge to the thermostat.
THE PECO WAVE WIRELESS SYSTEM™
The PECO Wave Wireless System is comprised of the TW205 or TW206 wireless thermostat
paired with a RW205 receiver. Optional accessories to the system are the SW205 wireless
occupancy sensor and SW206 wireless door switch.
The TW205 thermostat is a nonprogrammable digital thermostat that may be powered by
battery, 24 VAC, or both. It features separate heating and cooling setpoints, auto changeover,
fan control functions, and wireless communication with the RW205 receiver. The RW205
receiver is wired to the HVAC equipment and controls all outputs. The optional SW205
occupancy sensor and SW206 door switch also communicate wirelessly with the RW205
receiver to signal occupancy status.
The TW206 thermostat is the programmable model. It includes all the features of the TW205
thermostat plus 7-day programming, four time periods per day, and hold/override options.
APPLICATIONS AND FEATURES
The PECO Wave Wireless System is intended for use in PTAC, PTHP, and On/Off control
applications.
• System mode selections: Off-Heat-Cool-Auto-Setback
• Stages: 1 Heat/1 Cool, 2 Heat/1 Cool, 1 Heat/2 Cool
• 6 outputs (RW205): 1 Heat, 1 Cool, Up to 3 Fan, Outside Air Damper / Reversing Valve
• Fan control: 1-3 Speeds, Cycling (Auto) or Continuous (On)
• Permanent memory: The thermostat does not need batteries to store user-confi gured
settings in memory. Nonvolatile memory (EEPROM) saves temperature setpoints, fan, and
system settings for unlimited time. In the event of power loss, time settings are kept for at
least one year (TW206).
• Connections for Remote Temperature Probe and Setback (RW205)
FRONT PANEL REFERENCE
Liquid crystal display
with blue blacklight
System button
Fan button
Device connection
indicator lights
Connect button
(use paperclip
tip to depress)
© COPYRIGHT 2009 PECO, INC. ALL RIGHTS RESERVED.
TW205-206 WIRELESS THERMOSTAT
Aux
AUTO
OFF
HEAT
Up/ down buttons
COOL
FAN
SETBACK
Auto ON
Fahrenheit/ Celsius
temperature display
F/C
F/C
button (TW205) or
Program button
(TW206)
TW205 Thermostat
RW205 Receiver
INSTALLATION INSTRUCTIONS
!
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE OR SERVICE THIS THERMOSTAT.
Failure to observe safety information and comply with instructions could result
in PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.
To avoid electrical shock or damage to equipment, disconnect power before
installing or servicing and use only wiring with insulation rated for full thermostat
operating voltage.
Before installing this control, the Voltage Selection Switch must be placed in the
correct position. See instructions.
To avoid potential fi re and/or explosion do not use in potentially fl ammable or
explosive atmospheres.
Retain these instructions for future reference. This product, when installed,
will be part of an engineered system whose specifi cations and performance
characteristics are not designed or controlled by PECO. You must review your
application and national and local codes to assure that your installation will be
functional and safe.
SPECIFICATIONS
Temperature Range:
Differential:
Input Power:
Input Power (cont.):
Wireless Type:
Wireless Range:
Operating Temperature:
Shipping Temperature:
Operating Humidity:
Physical Dimensions:
WAVE WIRELESS SYSTEM MOUNTING CONSIDERATIONS
When selecting mounting locations for Wave Wireless System components, it is important
to consider the number and types of obstructions between components. The Wave Wireless
System will communicate through walls and other obstructions but they will reduce the
effective operating range of these devices. Mounting any device within a metal enclosure
may signifi cantly reduce its communicating range. The Wave Wireless System uses
Frequency Hopping technology to improve its resistance to wireless interference; however,
malfunctioning or improperly used wireless devices may interfere with the Wave Wireless
System. Take note of any other wireless devices in use near the Wave Wireless System
before installation or if communication errors occur frequently.
INSTALLATION
STEP 1 OF 4: THERMOSTAT WIRING AND MOUNTING
Mounting Location
The thermostat should be used indoors only. It should be mounted on an inner wall in
a location with freely circulating air, and where it will be responsive to changes in room
temperature. Avoid mounting near heat generating appliances (i.e. TV, heater, refrigerator),
or in direct sunlight.
Power Options
The thermostat will operate on either 24 VAC power or two AA alkaline batteries. Follow
instructions for chosen power option in the appropriate section below. If desired, thermostat
may operate on 24 VAC power with battery backup (follow the 24 VAC Power instructions).
WARNING
50° to 90°F (10° to 32°C)
1°F (0.5°C)
TW205 / TW206 thermostat: Two AA alkaline
batteries or 24 VAC, 50/60 Hz
RW205 receiver: 24 VAC or 100-277 VAC, 50/60 Hz
902 to 928 MHz Band, FHSS
(Frequency Hopping Spread Spectrum)
100 ft minimum in open air
0° to 120°F (-17° to 48°C)
-20° to 130°F (-28° to 54°C)
5% to 95% RH, non-condensing
TW205 / TW206: 4.5"H x 5.75"W x 1.1"D
RW205: 4.8"H x 3.8"W x 1.3"D
P/N 69512 3220-3139 REV 0 PAGE 1

Advertisement

Table of Contents
loading

Summary of Contents for Peco TW205-206

  • Page 1 7-day programming, four time periods per day, and hold/override options. functional and safe. APPLICATIONS AND FEATURES The PECO Wave Wireless System is intended for use in PTAC, PTHP, and On/Off control applications. • System mode selections: Off-Heat-Cool-Auto-Setback SPECIFICATIONS •...
  • Page 2 If you are only attempting to add a SW205 occupancy sensor or SW206 door switch 1. Mount thermostat backplate to the wall using the enclosed mounting screws. Tighten to an existing PECO Wave Wireless System, a 5-second connection process can be screws evenly but do not over tighten.
  • Page 3 1-60 Minutes 25 Minutes Defi nes the duration in which fan will be off. Fan Off Time will be activated after Fan On Time has passed. © COPYRIGHT 2009 PECO, INC. ALL RIGHTS RESERVED. P/N 69512 3220-3139 REV 0 PAGE 3...
  • Page 4: Application Notes

    • If the reversing valve needs to be energized with a demand for cooling, set Service Menu #41 to “2”. Note: When using the PECO Wave Wireless System with systems that use the OA/RV OUTPUT for heating or cooling, the outside air damper operation function is not available.
  • Page 5 The thermostat automatically selects the appropriate Heat or Cool mode depending upon the setpoint (desired temperature) and zone temperature (actual temperature). Turns the system off by disabling all outputs on the RW205. © COPYRIGHT 2009 PECO, INC. ALL RIGHTS RESERVED. P/N 69512 3220-3139 REV 0 PAGE 5...
  • Page 6: Instrucciones De Instalación

    Si no observa con la información de seguridad y cumple con las instrucciones podría ocasionar LESIONES PERSONALES, LA MUERTE O DAÑOS A LA El sistema PECO Wave Wireless está formado de un termóstato inalámbrico TW205 o TW206 PROPIEDAD. complementado con un receptor RW205. Algunos accesorios opcionales del sistema son un •...
  • Page 7: Instalación

    Si ésta es una instalación nueva o si intenta reemplazar cualquier componente en la caja de conexiones Placa de refuerzo existente en un sistema PECO Wave Wireless, debe realizar un proceso de conexión con dos tornillos de 10 segundos. Un proceso de conexión de 10 segundos borrará todos los dispositivos acoplados previamente de la memoria del RW205.
  • Page 8 Defi ne la duración en la que el ventilador estará apagado. El tiempo de apagado del ventilador se activará ventilador después de que haya transcurrido el tiempo de encendido del ventilador. © COPYRIGHT 2009 PECO, INC. TODOS LOS DERECHOS RESERVADOS. P/N 69512 3220-3139 REV 0 PÁGINA 8...
  • Page 9: Notas De Aplicación

    Sistemas que utilizan 1 CALEFACCIÓN y 1 ENFRIAMIENTO dedicados y no requieren salidas secundarias o escalonadas: Nota: Al utilizar el sistema PECO Wave Wireless con los sistemas que utilizan la SALIDA 1. En el receptor RW205: OA/RV para calefacción y enfriamiento, la función de funcionamiento del regulador de aire •...
  • Page 10 • Modo de reajuste automático: El termóstato TW205 se puede utilizar con los dispositivos de detección de ocupante inalámbrico PECO AUTO SW205/206. Esos dispositivos controlan automáticamente el modo de reajuste.
  • Page 11 Le non-respect des directives de sécurité et de se conformer aux instructions peut Le système sans fi l par onde de PECO comprend le thermostat sans fi l TW205 ou TW206 et entraîner des BLESSURES CORPORELLES, LA MORT ET/OU DES DOMMAGES un récepteur RW205.
  • Page 12: Installation

    Si vous essayez d’ajouter un capteur d’occupation SW205 ou un interrupteur de porte SW206 à un système sans fi l par onde PECO existant, une procédure de 5 seconde doit être effectuée. Enfoncez la touche CONNECT pendant 5 seconde ou jusqu’à ce que les témoins lumineux se mettent à...
  • Page 13 Détermine la période pendant laquelle le ventilateur sera en arrêt. La période d’arrêt du ventilateur sera activée dès intermittent que le temps de marche du ventilateur sera écoulé. © COPYRIGHT 2009 PECO, INC. TOUS DROITS RÉSERVÉS. Réf. 69512 3220-3139 RÉV. 0 PAGE 13...
  • Page 14: Notes De Fonctionnement

    • Réglez la fonction no 41 du menu à « 0 ». le système sans fi l de PECO avec des systèmes utilisant des SORTIE OA/VR pour le (Dans ce cas, la fonction OA/VR (air extérieur/robinet inverseur) peut servir à contrôler un chauffage et la climatisation.
  • Page 15 • Mode automatique de remise au point de consigne: Le thermostat TW205 peut être utilisé avec les appareils de détection d’occupation HEAT sans fi l PECO SW205/206. Le mode de remise au point de COOL consigne est automatiquement contrôlé par ces appareils. Pour plus d’information, voir les «...

Table of Contents