Display
Function
L 2
LOOP 2:
If you activate this function, the loop con-
nected to Loop2 input will have the SAFETY
/CLOSE function, i.e. it will operate as SAFETY
during the closing stage, and will command
CLOSE to the board at release.
Y
= loop2 active
n o
= loop2 not active
Attention: if the function is not activated, loop2
status will nevertheless be available on one of the
outputs, if appropriately set
S 1
NO EFFECT
S2
NO EFFECT
S t
AUTOMATED SYSTEM STATUS:
Exit from programming, storage of set data
and return to automated system status
view.
00
Closed
0 1
Opening pre-flashing
02
Opening
03
Open
04
On pause
05
Closing pre-flashing
06
Closing
07
Stopped ready to close
08
Stopped ready to open
09
Emergency opening
10
Closing safety device in operation
5.2. 2
LEVEL PROGRAMMING
nd
To access 2
LEVEL PROGRAMMING, press push-button F and, while
ND
holding it down, press push-button +.
if you release the push-button +, the display shows the name
of the first function.
if you also release the F push-button, the display shows the
value of the function, which can be changed with keys +
and -.
if you press the F key (and hold it down), the display shows
the name of the next function; if you release it, the value is
shown and can be modified with keys + and -.
when you reach the last function, press the F push-button
to exit programming, and the display resumes showing the
inputs status.
Default
no
.
05
05
The following table indicates the sequence of functions accessible
in 2
LEVEL PROGRAMMING:
nd
2
LEVEL PROGRAMMING
nd
Display
Function
bo
MAXIMUM TORQUE AT THRUST:
the motor works at maximum torque
(ignoring the torque adjustment) during
the initial time of the movement.
Y
= Active
no
= Excluded
PF
PRE-FLASHING:
to activate the flashing light for 5 sec be-
fore the start of the movement
no
OC
CL
PA
SC
SLOW CLOSING:
for setting the entire closing stage at slow
speed.
Y
= Active
no
tr
DECELERATION TIME AFTER LIMIT-SWITCHES:
for setting deceleration time (in seconds)
after the opening and closing limit-switches
have operated.
Can be adjusted from
second steps.
00
= deceleration excluded
10
= maximum deceleration
t
WORK TIME (time-out):
We advise you to set a value from 5 to
10 seconds longer than the required by
the automated system to move from the
closing to the opening position and vice
versa.
Can be adjusted from
one second steps.
Next, the viewing changes in minutes and
tenths of a second (separated by a dot)
and time is adjusted in 10 second steps,
up to the maximum value of
FS
FAIL SAFE:
If this function is activated, it enables a
function test of the photocells before any
automated system movement, indepen-
dently from the output used . If the test fai-
ls , the automated system does not start
the movement.
Y
= Active
no
= Excluded
o 1
OUTPUT 1:
The output can be set to one of the fol-
lowing functions:
00
FAILSAFE
01
INDICATOR LIGHT (lighted at ope-
ning and pause, flashing at closing, and
off when automated system closed)
02
Beam LIGHT
beam closed and on pause, inactive with
beam open, flashing during movement)
03
Beam CLOSED
04
Beam OPEN or in PAUSE, it goes
OFF during closing pre-flashing.
05
Beam
pre-flashing included.
06
Beam MOVING AT CLOSING, pre-
flashing included.
07
Beam STILL
08
Beam in EMERGENCY status
09
LOOP1 engaged
10
LOOP2 engaged
1 1
OPEN for 624 SLAVE
12
CLOSE for 624 SLAVE
13
Beam DETACHED
16
excluded
before every movement
before closing
at end of pause only
= Excluded
0
10
to
sec. in one
0
59
to
sec. in
4.1
minutes.
(output active with
LIGHT H T E D
MOVING
AT
OPENING,
Default
Y
no
no
03
20
no
00

Advertisement