    • conforms to the essential safety requirements of the following EEC directives 2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility Directive Additional note: This product has undergone testing in a typical standard configuration (all products built by FAAC S.p.A. ) Bologna, 01-08-2013 The Managing Director A. Marcellan WARNINGS •...
  • Page 3: Warnings

    Thanks to encoder control and opening and closing limit switches, if correctly used, it can guarantee installation in conformity with current safety regulations. The E550 SLAVE control board is an interface for the second motor, on which the courtesy light is also installed. 2 TECHNICAL SPECIFICATIONS...
  • Page 4: Electrical Connections

    3 sec. E550 6 = FCC = Closing limit switches contact (N.C.). The closing Limit switch consists of a micro-pushbutton which, activated by the cam when the door reaches clo-...
  • Page 5: Connector J4 (Low Voltage)

    8 = FSW CL = Closing Safety devices contact (N.C.) 6 SIGNALLING LEDS (status of inputs) Safety devices are all devices (photocells, sensitive ed- ges,…) with N.C. contact, which, if there is an obstacle A two-digit display is installed on the board. During normal in the area they protect, operate to reverse door closing operation, it indicates the status of the inputs.
  • Page 6: Basic Programming

    (black and brown cables) of the board. For two-operator applications: assign the same wire colours to the “COM,OP ,CL” terminals of the E550 board and of the SLAVE board, and, if you have to change over the phases, change them over for both motors.
  • Page 7: Advanced Programming

    7.4 ADVANCED PROGRAMMING To access ADVANCED PROGRAMMING, use push-button F and +: 1) press push-button F and, while holding it down, press push-button +. 2) if you release the push-button +, the display shows the name of the first function ( 3) if you release the F push-button, the display shows the value of the function, which can be changed with keys + and -.
  • Page 8 Tab. 3 ADVANCED PROGRAMMING Display Function dF01 POSITION OF DOOR: Shows the position of the door during motorised movement from For an explanation of parameter refer to chapter 7.5 UPPER LIMIT OF ZONE A: Defines the upper limit of zone , in which to subsequently adjust the force, speed and sensitivity functions of the encoder (input value...
  • Page 9: Automated System Test

    Otherwise, change the force, speed and sensitivity parameters in order to be again within the set values. 9 OPERATION OF ENCODER AND ELECTRONIC CLUTCH (ANTI-CRUSHING) Thanks to encoder control and an electronic system for adjusting motor torque, the E550 board, if correctly used, guarantees installation conforming to current safety regulations.
  • Page 10: Function Logics

    10 FUNCTION LOGICS Tab. 4/a LOGIC “E” PULSES STATUS OF THE OPEN FSW CL FSW OP STOP AUTOMATED SYSTEM no effect no effect no effect CLOSED opens (inhibits opening) (inhibits opening) (function excluded) OPENING stops operation no effect stops operation programming no effect OPEN...