Advertisement

MASTER-T &
MASTER-T &
SLAVE-T
SLAVE-T

Advertisement

Table of Contents
loading

Summary of Contents for FAAC MASTER-T

  • Page 1 MASTER-T & MASTER-T & SLAVE-T SLAVE-T...
  • Page 2: Ec Declaration Of Conformity For Machines

    18) FAAC declines all liability as concerns safety and efficient operation of source of danger. the automated system, if system components not produced by FAAC are 6) FAAC declines all liability caused by improper use or use other than that for used. which the automated system was intended.
  • Page 3 The SLAVE-T control board (required on 2-leaf gates only) is controlled by the MASTER-T control board to which all accessories and pulse generators are connected. The MASTER-T board can be programmed and is used to set the following: function logics, work times (by self-learning) and pause times, leaf speed, and the sensitivity of the anti-crushing device.
  • Page 4 DESCRIPTION OF SYSTEM - ELECTRICAL 12 Vdc flashing lamp EQUIPMENT (standard system) Receiver Key operated push-button MASTER-T SLAVE-T control board control board Left-hand Right-hand DOMO DOMO operator operator Differential Tx photocell Rx Photocell thermal breaker Fig. 3 3 x 0,5...
  • Page 5 The MASTER-T board positioning has to be decided before installing the control board enclosures since all accessories will be connected to this board. The MASTER-T board can be fitted either on the right or on the left side of the gate. You only have to decide to which leaf it will be associated as shown in Fig. 5.
  • Page 6 -Always separate 230Vac power cable from control and safety cables (push-buttons, receiver, photocells, etc.). To avoid any electric noise, use separate sheaths or a shielded cable (with earthed shield). SLAVE-T CONTROL BOARD MASTER-T CONTROL BOARD Programming LED Diagnostics LED ( LED P )
  • Page 7: Electrical Connections

    (Opening safety devices contact) Photocells (e.g. SAFEBEAM) (1) FSW CL (Closing safety devices contact) Photocells (e.g. SAFEBEAM) (1) (MASTER-T - SLAVE-T connection) 7 - 8 (positive for 24V power supply) Accessories MAX total absorption of 150mA 9 - 11 W.L.
  • Page 8 Closing safety devices Opening safety devices Fig. 9 Fig. 11 Attention : a maximum of 2 pairs of SAFEBEAM photocells can be connected to the MASTER-T board Examples of photocell connections 1 pair of CLOSING connection of 1 pair of OPENING photocells...
  • Page 9 Connection of DECODER, MINIDEC, RP cards Status of inputs 12.3 The MASTER-T board has a function for checking the status of Insert the DECODER, MINIDEC or RP decoding card in the block inputs on the terminal board. connector J6 (Fig. 7), with the components facing up (Fig. 13 In all LEDs OFF status (LEDs both with letters and numbers), press shows the connection of cards RP433DS).
  • Page 10 12.4.1 Leaf 1 management with MASTER-T or SLA- 12.4.3 Pause Times VE-T board In all LEDs OFF status, press and hold Press push-button P1 again and down push-button P1, and press LED B will light together with LED 1. push-button P2 - LED A begins to flash.
  • Page 11 If you press push-button P2 for 1 second, command at the required point with a the MASTER-T leaf and the SLAVE-T leaf further pulse from P2. will begin to move together until the opening mechanical stop-point reached.
  • Page 12: Maintenance

    12.5 Status of indicator light If you wish to use a 12V-0.5W indicator light (terminal 9 - 11 of J1, see Fig. 8), the following table shows the statuses of the indicator light according to gate position. Tab. 4 - Statuses of indicator light Indicator-light status Gate status Light Off...
  • Page 14: Troubleshooting

    The gate will stay locked until mains MASTER-T boar and SLAVE-T board. power returns. MASTER-T and SLAVE-T board LED P OFF Automated system shut down. STOP (3) and FSW (4 and 5) terminals not Check the wiring as shown in the connected.
  • Page 16 Le descrizioni e le illustrazioni del presente manuale non sono impegnative. La FAAC si riserva il diritto, lasciando inalterate le caratteristiche essenziali dell’apparecchiatura, di apportare in qualunque momento e senza impegnarsi ad aggiornare la presente pubblicazione, le modifiche che essa ritiene convenienti per miglioramenti tecnici o per qualsiasi altra esigenza di carattere costruttivo o commerciale.

This manual is also suitable for:

Slave-t