4. ELECTRICAL CONNECTIONS
BEAM BREAKING
FCC
FCA
OPEN
CLOSE
4.1. CONNECTION OF PHOTOCELLS AND SAFETY DEVICES
Before you connect the photocells (or other devices) we advise you
to select the type of operation according to the movement zone
they have to protect.
Closing safety devices:
they are tripped only during the barrier
closing movement, and, therefore, are suitable for protecting
the closing zone against the risk of impact.
If two or more safety devices (NC contacts) have
to be connected, put them in series with each
other (see fig.3).
Connection of 2 NC contacts in series
(E.g.: Photocells, Stop)
If two or more safety devices with N.O. contacts
have to be connected, put them in parallel with
each other (see fig.4).
Connection of 2 N.O. contacts in parallel
(E.g.: Open A, Open B)
J6
J5
J3
1
2
3
4
5
6
7
8
9
J1
STOP
EMERGENCY
Fig. 3
Fig. 4
10 11
12 13
14
15
16 17
18
19
24Vdc
3W
To connect the
photocells and
safety devices,
consult paragraph
4.1.
Connection of two pairs of closing photocells
Connection of 1 pair of closing photocells
13
MOTOR THRUST
CAPACITOR
J8
J2
20
21
22
23
24
25
26
MOTOR
FAN
230Vac
max 60W
J9
PE
N
L
230Vac
50Hz
Fig. 2
Fig. 5
Fig. 6