Control Unit - FAAC 624BLD Manual

Hide thumbs Also See for 624BLD:
Table of Contents

Advertisement

1. WARNINGS
Attention: Before attempting any work on the control unit (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
- Connect the earth cable to the terminal on the J9 connector of the unit (see fig. 2).
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical noise, use
separate sheaths or a screened cable (with the screen earthed).
2. TECHNICAL SPECIFICATIONS
P o w e r s u p p l y v o l t a g e
A b s o r b e d p o w e r
M o t o r m a x . l o a d
P o w e r s u p p l y f o r a c -
c e s s o r i e s
A c c e s s o r i e s m a x .
c u r r e n t
A m b i e n t t e m p e r a t u r e
F u s e s
F u n c t i o n l o g i c s
W o r k t i m e
P a u s e t i m e
M o t o r p o w e r
T e r m i n a l b o a r d i n p u t s
C o n n e c t o r i n p u t s
T e r m i n a l b o a r d
Power supply 24 Vdc, Fail-safe, Status output,
o u t p u t s
R a p i d c o n n e c t o r
P r o g r a m m i n g
Logics, Pause Time, Power, Loop 1 and 2, Thrust
torque, Pre-flashing, Slow closure, Deceleration
P r o g r a m m a b l e
time, Work time, Indicator light output, Fail-safe
f u n c t i o n s
output, Status output, BUS output, Assistance

CONTROL UNIT

230 Vac (+6% -10%) - 50 Hz
7 W
300 W
24 Vdc
500 mA
-20°C - +55°C
F1 = F 5A - 250V F2 = T 0.8A - 250V
Automatic, Automatic 1, Semiautomatic,
Parking, Parking-Automatic,
Condo, Condo-automatic
FAAC-CITY, Dead-man, Remote, Custom
Programmable (from 0 to 4 minutes)
Programmable (from 0 to 4 minutes)
Programmable on 50 levels
Loop1, Loop2, Open, Close,
Closing safety devices, Stop, Emergency,
Power supply 230Vac + Earth
Opening and closing limit-switch, Detector
Motor capacitor, Beam detachment sensor
Flashing light, Fan, Motor,
Indicator light 24 Vdc, BUS
5-pin Minidec board coupling, Decoder,
Receiver RP/RP2
No. 3 keys (+, -, F) and display
request
624 BLD
3. LAYOUT AND COMPONENTS of 624 BLD
TF1
F2
+
-
DL
F
J4
LOOP DETECTOR
J11C
3.1 DESCRIPTION OF COMPONENTS
DL
SIGNALS AND PROGRAMMING DISPLAY
LED
INPUT STATUS CONTROL LEDs
J1
LOW-VOLTAGE TERMINAL BOARD
TERMINAL BOARD FOR CONNECTION OF MOTOR,
J2
FLASHING LIGHT AND FAN
J3
OPENING LIMIT-SWITCH CONNECTOR
J4
CONNECTOR: DECODER
J5
CLOSING LIMIT-SWITCH CONNECTOR
J6
CONNECTOR FOR ROD BREAKING SENSOR
J8
CONNECTOR FOR MOTOR THRUST CAPACITOR
J9
TERMINAL-BOARD FOR 230 VAC POWER SUPPLY
J11
CONNECTOR EXTERNAL LOOP DETECTOR
FUSE FOR MOTORS AND TRANSFORMER PRIMARY
F1
WINDING (F 5A)
F2
FUSE FOR L OW VOL T AGE AND ACCESSORIES (T 800mA)
F
PROGRAMMING PUSH-BUTTON "F"
+
PROGRAMMING PUSH-BUTTON "+"
-
PROGRAMMING PUSH-BUTTON "-"
TF1
TRANSFORMER
12
F1
J9
J8
J2
EMERG - DL5
STOP - DL4
FSW - DL3
J1
CLOSE - DL2
LED
OPEN - DL1
PIVOT - DL8
FCA - DL6
FCC - DL7
J6
J3
J5
J11A
J11B
Fig. 1
MINIDEC / RP RECEIVER