Device/VLAN Configuration Screen
The following defines each field of the Device/VLAN Configuration
screen:
Forward Default VLAN Out All Ports (Toggle)
Allows the Administrator to assign or remove the default VLAN from the
Port VLAN List for all ports. When set to YES, the default VLAN is
added to the Port VLAN List of all ports that do not already include it.
When set to NO, the default VLAN is removed from the Port VLAN List
of any port that does not have the default VLAN as its PVID. The default
is NO.
VLAN ID - upper part of screen (Read-Only)
Provides a list of the assigned VLAN IDs that are configured in the
module. Initially, only the Default VLAN (VLAN ID: 1) is listed.
FID - upper part of screen (Read-Only)
Lists the Filtering Database ID (FID) associated with each VLAN.
VLANs associated with the same FID may enable the users in those
VLANs to communicate with each other.
VLAN Name - upper part of screen (Read-Only)
Lists the names assigned to the corresponding VLAN IDs. If a name has
not been assigned to a VLAN, the VLAN Name field displays, "Not
Defined".
Admin Status (Toggle)
The current state of the associated VLAN. This field toggles between
Enabled and Disabled. An enabled VLAN is operational and a disabled
VLAN is not operational. If a VLAN is disabled, all ports assigned to that
VLAN will assume a PVID of the default VLAN.
VLAN ID - lower part of screen (Modifiable)
Accepts input from the user to select or define a new VLAN ID.
FID - lower part of screen (Modifiable)
Displays the FID currently associated with the VLAN typed in the
VLAN ID field. A new number can be typed into the FID field to reassign
the VLAN to a different filtering database. Each VLAN will default to a
FID that matches its VLAN ID and can be changed to a FID from 1 to
1094.
802.1Q VLAN User's Guide
3-9