Download Print this page

IDTECK Star 505R Quick Install Manual page 4

Hide thumbs Also See for Star 505R:

Advertisement

RF Only, RF + P/W mode: Register Card & P/W
PIN-Only mode: Register PIN (4 ~ 6 digits) – Not applicable for the SR505.
< INPUT THE ID INFORMATION >
ID: RF-Only, RF + P/W mode – Card Reading by the reader
PIN Only: Register PIN (4 ~ 6 digits) – Not applicable for the SR505.
TS: Time Schedule code (Enter the default setting value "00")
- Enter such code for applying T/S
RD: Setup to use the reader or not (Enter the default setting value "3")
1 – To be read only by the reader of 505R
2 – To be read only by the outer reader
3 – To be read by the both readers
3.5 Delete Card (Select "ID DELETE" Menu by the Key '4' or '6')
ID DELETE
Display for ID Delete
Present the card for reading or enter 4~6-digit No. for deleting.
PIN only mode: 4 ~ 6-digit No. – Not applicable for the SR505.
RF-only, RF+PW mode: 8-digit (SR505: 10-digit) card No.
4. Normal Operation
4.1 Power ON
When the power is applied to 505R, the Red LED (LED1) is turned on.
4.2 Registered card reading
When a registered card (or PIN) is read, the Door (Relay 1) will be opened for 3 seconds (Default)
with the Green LED (LED2) light on.
4.3 Exit Button
The Exit Button or the Exit Reader should be installed inside.
When the Exit Button is pressed, the door will be opened for 3 seconds with the Green LED (LED2) light on.
4.4 Alarm (Unregistered ID /PW Error / TS Error / Door Error)
When an unregistered card is read, or any wrong password is input, or any error over the time schedule and the
door access is occurred, the access is denied and the alarm will be activated for 3 seconds (Default) with the
Yellow LED (LED 3) light on.
1
2
ENT
3
Enter Card No.
->__________
LED1: Power ON/OFF Status
LED2: Door Relay Status
LED3: Alarm Relay Status
4