APPENDICES
Number
Name
Safety station
interlock
SD1076
cancel request
to
(CC-Link
SD1079
Safety master
module 1)
Safety remote
station
SD1200
specification
to
(CC-Link
SD1203
Safety master
module 2)
Safety station
refresh
SD1204
communication
to
status (CC-Link
SD1207
Safety master
module 2)
Safety station
SD1208
communication
to
status (CC-Link
Safety master
SD1271
module 2)
App
- 18
Appendix 2 Special Register List
TableApp.17 Special register
Meaning
Cancel the I/O interlock of safety station by changing the bit of
register from 0 to 1.
0: Not cancel the
I/O interlock
of safety
SD1076
station
SD1077
1: Cancel the I/O
interlock of
SD1078
safety station
SD1079
• The specified status of safety remote station is stored.
• "0" is stored for the standard remote station.
0: No safety
remote station
SD1000
specification
1: Safety remote
SD1001
station
SD1002
specification
SD1003
• The refresh communication status of safety remote station is
stored.
0: Normal,
• "0" is stored for the standard remote station.
Reserved
station
specified,
Unused,
SD1204
Standard
SD1205
remote station
1: Safety station
SD1206
communication
SD1207
error
• The status of communication with each safety remote station
is stored.
• SD1208: Station number 1 to SD1271: Station number 64 (0
fixed in the case of standard remote station, reserved station
specified, or without connection)
0: At normal communication
10: At initial
20: During internal information access
30: Link error
The status of
8300: The safety communications - Safety remote station
communication
detection error
with safety
8310: The safety communications - Product information
station is stored.
mismatch
8320: The safety communications - Initial monitor timeout
8321: The safety communications - Safety monitor timeout
8322: The safety communications - Error monitor timeout
8330: The safety communications - Command error
8331: The safety communications - Data numbering error
8332: The safety communications - Link ID error
8333: The safety communications - Running number error
8334: The safety communications - Received data error
Explanation
b15
b14
-
16
15
to
32
31
to
48
47
to
64
63
to
1 to 64 in the table indicate station numbers.
b15
b14
-
16
15
to
32
31
to
48
47
to
64
63
to
1 to 64 in the table indicate station numbers.
b15
b14
-
16
15
to
32
31
to
48
47
to
64
63
to
1 to 64 in the table indicate station numbers.
Set by
(When set)
b1
b0
2
1
U (Request)
18
17
34
33
50
49
b1
b0
2
1
S (Initial)
18
17
34
33
50
49
b1
b0
S (Status
2
1
changel)
18
17
34
33
50
49
S (Status
changel)
Corresponding