Viessmann PLC VITOCAL 350-HT PRO Service Instructions For Contractors page 33

Heat pump control unit
Table of Contents

Advertisement

Overview of fault messages
ID
Fault message
49
"Sensor fault,oil press.2"
50
"Sensor fault,oil press.3"
51
"Sensor fault, room temp"
52
"Soft starter 1 faulty"
53
"Soft starter 2 faulty"
54
"Soft starter 3 faulty"
55
"Oil press. diff. 1 too low"
56
"Oil press. diff. 2 too low"
57
"Oil press. diff. 3 too low"
58
"Winding protectn 1 trig."
59
"Winding protectn 2 trig."
60
"Winding protectn 3 trig."
61
"High press. switch 1 trig."
62
"High press. switch 2 trig."
63
"High press. switch 3 trig."
64
"Refrig. leak, pre-alarm"
65
"Suct. switching act."
66
"Fault, oil sump heater 1"
(cont.)
Effects
Compressor 2 remains shut
down for as long as the fault is
current
Compressor 3 remains shut
down for as long as the fault is
current
The room temperature cannot
be measured
Compressor 1 switches off and
attempts to start up again after
the restart block
Compressor 2 switches off and
attempts to start up again after
the restart block
Compressor 3 switches off and
attempts to start up again after
the restart block
Compressor 1 remains shut
down until the fault is acknowl-
edged
Compressor 2 remains shut
down until the fault is acknowl-
edged
Compressor 3 remains shut
down until the fault is acknowl-
edged
Compressor 1 remains shut
down until the fault is acknowl-
edged
Compressor 2 remains shut
down until the fault is acknowl-
edged
Compressor 3 remains shut
down until the fault is acknowl-
edged
Compressor 1 remains shut
down until the fault is acknowl-
edged
Compressor 2 remains shut
down until the fault is acknowl-
edged
Compressor 3 remains shut
down until the fault is acknowl-
edged
Room ventilation is switched on
The application limits are not be-
ing observed
Compressor 1 switches on auto-
matically as soon as the fault is
no longer current
Troubleshooting
Possible cause
The oil pressure sensor of com-
pressor 2 is faulty
The oil pressure sensor of com-
pressor 3 is faulty
Room temperature sensor faulty
Soft starter of compressor 1 is
faulty
Soft starter of compressor 2 is
faulty
Soft starter of compressor 3 is
faulty
Oil pressure differential in com-
pressor 1 is too small
Oil pressure differential in com-
pressor 2 is too small
Oil pressure differential in com-
pressor 3 is too small
Winding protection of compres-
sor 1 is faulty
Winding protection of compres-
sor 2 is faulty
Winding protection of compres-
sor 3 is faulty
High pressure switch of com-
pressor 1 is faulty
High pressure switch of com-
pressor 2 is faulty
High pressure switch of com-
pressor 3 is faulty
The refrigerant sensor has meas-
ured an average concentration of
refrigerant in the air
Suction switching is still active in
the visualisation
The oil sump heater of compres-
sor 1 was switched off for too
long
33