Beretta EXCLUSIVE Installer And User Manual page 17

Table of Contents

Advertisement

C.A.I.: programmable parameters
DESCRIPTION PARAMETERS
PAR.
1
GAS TYPE
3
INSULATION LEVEL OF BUILDING (+) (*)
10
DHW MODE
11
DHW CIRCUIT MAXIMUM SET-POINT
12
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
13
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
14
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
20
CH MODE
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
40
DHW THERMOSTAT OPERATING MODE
41
DHW PREHEATING FUNCTION
42
S.A.R.A. FUNCTION
43
S.A.R.A. BOOSTER FUNCTION
44
THERMOREGULATION FUNCTION
45
INCLINATION THERMOREGULATION CURVE (OTC) (*)
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
85
SEMI-AUTOMATIC FILLING
86
AUTOMATIC FILLING PRESSURE (ON)
MIX C.S.I.: programmable parameters
DESCRIPTION PARAMETERS
PAR.
1
GAS TYPE
2
BOILER POWER
3
INSULATION LEVEL OF BUILDING (+) (*)
10
DHW MODE
11
DHW CIRCUIT MAXIMUM SET-POINT
12
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
13
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
14
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
20
CH MODE
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
40
DHW THERMOSTAT OPERATING MODE
41
DHW PREHEATING FUNCTION
42
S.A.R.A. FUNCTION
43
S.A.R.A. BOOSTER FUNCTION
44
THERMOREGULATION FUNCTION
45
INCLINATION THERMOREGULATION CURVE (OTC) (*)
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
85
SEMI-AUTOMATIC FILLING
86
AUTOMATIC FILLING PRESSURE (ON)
(*) parameters shown only with external sensor connected and parameter 44 in 1 (AUTO).
(+) for well-insulated buildings select values close to 20, for badly insulated buildings choose values close to 5.
Parameter 45 "Inclination of thermoregulation curve (OTC)"
The curve must be chosen according to the geographical area and the type of
installation.
UNIT OF
MIN
MEASURE
1 Methane
2 LPG
3 Methane France
min
5
0 (OFF)
1 (Instantaneous)
2 (Mini-tank)
3 (External water-tank with thermostat)
4 (External water-tank with sensor)
° C
40
0 (OFF)
1 (ON)
2 (zone valves + remote control panel)
° C
40
min
0
min
0
-
0
0 (OFF)
1 (AUTO)
2 (ON)
0 (OFF)
1 (AUTO)
2 (ON)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2,5
°C
0
°C
0
0 (disabled)/1 (enabled)
bar
0.4
UNIT OF
MIN
MEASURE
1 Methane
2 LPG
3 Methane France
26 (26kW)
30 (30kW)
34 (35kW)
min
5
0 (OFF)
1 (Instantaneous)
2 (Mini-tank)
3 (External water-tank with thermostat)
4 (External water-tank with sensor)
° C
40
0 (OFF)
1 (ON)
2 (zone valves + remote control panel)
° C
40
min
0
min
0
-
0
0 (OFF)
1 (AUTO)
2 (ON)
0 (OFF)
1 (AUTO)
2 (ON)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2,5
°C
0
°C
0
0 (disabled)/1 (enabled)
bar
0.4
Tm. - 20
OTC = 10 x
20 - Te.
17
MAX
DEFAULT
(setted in factory)
(setted by techn. assist. centre)
1-2
20
5
1
60
60
1
80
80
20
15
20
3
1
0
1
1
1
1
1
40
20
10
4
10
6
1
0.8
0.6
MAX
DEFAULT
(setted in factory)
(setted by techn. assist. centre)
1-2
26-30-34
20
5
1
60
60
1
80
80
20
15
20
3
1
0
1
1
1
1
1
40
20
10
4
10
6
1
0.8
0.6
T m. = maximum rated temperature of heating water
T e. = minimum rated external temperature
PARAMETERS
60
80
5
40
0
1
PARAMETERS
60
80
5
40
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C.a.i.R.a.i.Mix c.s.i.Mix r.s.i.

Table of Contents