OPTICOM LCDI-35T User Manual

OPTICOM LCDI-35T User Manual

Ip camera tester

Advertisement

Quick Links

LCDI-35T
IP CAMERA TESTER
USER MANUAL
(V01.00)
800-578-1853
www.opticomtech.com

Advertisement

Table of Contents
loading

Summary of Contents for OPTICOM LCDI-35T

  • Page 1 LCDI-35T IP CAMERA TESTER USER MANUAL (V01.00) 800-578-1853 www.opticomtech.com...
  • Page 2 Thank you for purchasing the LCDI-35T IP camera tester. Please read the manual before using the IP camera tester and make sure to follow all guidelines for proper use. For safe using use of the IP camera tester safely, please first please read the「Safety Information」section in the manual thoroughly.
  • Page 3: Table Of Contents

    CONTENT 1 .Safety information ----------------------------------------------------------------------------------------------------------- 1 2. IP Camera Tester Introduction ------------------------------------------------------------------------------------------ 2 2.1 General ---------------------------------------------------------------------------------------------------------------- 2 2.3 Packing list ------------------------------------------------------------------------------------------------------------ 3 2.4 Function interface --------------------------------------------------------------------------------------------------- 3 3. Operation ---------------------------------------------------------------------------------------------------------------------- 7 3.1 Installing the Battery ----------------------------------------------------------------------------------------------- 7 3.2 Instrument connection --------------------------------------------------------------------------------------------- 8 3.2.1 IP camera connection ------------------------------------------------------------------------------------ 8 3.2.2 Analog camera connection ------------------------------------------------------------------------------ 9 3.2.3 HD Coaxial camera connection ---------------------------------------------------------------------- 10...
  • Page 4 (1)IP address scan ------------------------------------------------------------------------------------------ 53 (2)PING Test -------------------------------------------------------------------------------------------------- 54 (3)Network test (Ethernet bandwidth test) ------------------------------------------------------------ 54 (4)Port Flashing ---------------------------------------------------------------------------------------------- 58 (5)DHCP server ---------------------------------------------------------------------------------------------- 59 (6)Trace route ------------------------------------------------------------------------------------------------ 59 (7)Link monitor ----------------------------------------------------------------------------------------------- 60 3.3.16 Rapid IP Discovery ------------------------------------------------------------------------------------ 61 3.3.17 PoE power / DC12V 2A power output ------------------------------------------------------------ 61 3.3.18 Cable Test------------------------------------------------------------------------------------------------ 62 3.3.19 RJ45 cable TDR test ---------------------------------------------------------------------------------- 63 3.3.20 Cable Tracer (*Optional ) ---------------------------------------------------------------------------- 66...
  • Page 5 3.3.38 Notepad --------------------------------------------------------------------------------------------------- 93 3.3.39 System Setting ------------------------------------------------------------------------------------------ 94 3.3.40 File explorer --------------------------------------------------------------------------------------------- 97 3.3.41 Theme ----------------------------------------------------------------------------------------------------- 99 3.4 Audio test---------------------------------------------------------------------------------------------------------- 101 3.5 PoE power output ----------------------------------------------------------------------------------------------- 101 3.6 DC12V 2A power output -------------------------------------------------------------------------------------- 102 4. Specifications------------------------------------------------------------------------------------------------------------- 104 4.1 General Specifications ---------------------------------------------------------------------------------------- 104 4.2 Multi-meter specifications ------------------------------------------------------------------------------------- 106 4.3 Optical power meter specifications ------------------------------------------------------------------------ 109 4.4 Visual fault locator specifications --------------------------------------------------------------------------- 109...
  • Page 6: Safety Information

    1. SAFETY INFORMATION ◆ This IPC tester is intended to be used in compliance with any local electrical codes and should not be used in areas where the use of electronics is prohibited, such as gas stations, hospitals ◆ To prevent electronics malfunctions or failures, this product should not be splashed with or submerged in liquids.
  • Page 7: Ip Camera Tester Introduction

    ◆ When selecting a manual voltage range, if you do not know the voltage beforehand, please use the highest voltage range before measuring. ◆ Always be careful when working with voltages above 60V DC or 40V AC, making sure to avoid direct skin contact with the metal part of the measuring probes.
  • Page 8: Packing List

    2.2 Packing list 1). Tester 2). AC Power Adaptor DC12V 2A 3). Network cable tester 4). Polymer lithium ion battery (7.4V DC 2800mAh) 5). BNC cable 6). RS485 cable 7). SC, ST connector (Only for optical power meter models)* 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models)* 9).
  • Page 9 Press and hold for more than 2 seconds to turn tester On or Off. A short press will turn the display on or off. Set key Menu key. Press to call up shortcut menu on Home screen. Far focus: Focus the image nearby - 4 -...
  • Page 10 Far focus: Focus the image faraway TELE: zoom in the image WIDE: zoom out the image Open/set, Confirm the setting of parameters, open or enlarge the aperture Return/Close: Return or cancel while setting parameters of the menu, close or decrease the aperture Upward, set function or add parameter.
  • Page 11 Top interface Left interface Right interface Video signal input(BNC interface)/ Video signal input, AHD, CVI and TVI input (BNC interface) (Optional) Video signal output(BNC interface)/ cable tracer interface (Optional) Visible red laser source emits Interface (Optional) / Optical power meter interface (Optional) - 6 -...
  • Page 12: Operation

    TDR cable test interface (Optional) DC12V 2A power output, for provisional DC power supply DC12V 2A charging interface LED flashlight (lamp) RS485 Interface: RS485communication for the PTZ UTP cable port: UTP cable tester port/ Cable tracer port Micro SD card moveable (supports up to 32GB) PoE power supply output or LAN test port (Use to test PoE or non-PoE IP camera) PSE power sourcing equipment.
  • Page 13: Instrument Connection

    instrument works abnormally. Multi-meter: the red and black multi-meter pen must insert the corresponding port. Warnings: Instrument communication port is not permitted access circuit voltage over 6V, otherwise damage the tester. Warnings: Not allow insert multi-meter pen in the current terminal to measure voltage. 3.2 Instrument connection 3.2.1 IP camera connection Power an IP camera with an independent power supply, then connect the IP camera to the IPC...
  • Page 14: Analog Camera Connection

    2) If use the tester’s menu to turn off the tester’s PoE power supply, the PoE switch and the power sourcing equipment are allowed to connect to the tester’s PSE port, and the PoE power will be supplied to the IP camera by the tester’s LAN port. On this condition, the tester cannot receive data from IP camera, but the computer connected to the PoE switch can receive the data via the tester.
  • Page 15: Hd Coaxial Camera Connection

    3.2.3 HD Coaxial camera connection * CVI, TVI, AHD camera are classified as HD coaxial cameras. Hereby the following instruction of how to connect TVI camera to the tester is also applied to CVI and AHD camera. (1) Connect the TVI camera's video output to the IP tester’s “TVI IN” interface, the image will display on the tester.
  • Page 16: Lite Mode & Normal Mode

    Lite mode & Normal mode 3.3.1 ◼ Lite mode: You can easily find corresponding apps ◼ In Lite mode, Press the icon several seconds, can move the icon to other apps ◼ In Lite mode, click the finger icon in the lower right corner to release lock icon, move icons and change function icons sequence.
  • Page 17: Drop-Down Menu

    Normal mode ◼ Tap the screen and slide left or right to change menu. Select Icons to enter, if quit, please click Click SD card, install or remove SD card. 3.3.2 Drop-down Menu Press and slide at right top right corner twice to open shortcut menu. The shortcut menu includes POE power output, IP settings, Wi-Fi, CVBS, Video OUT, LAN, Brightness, settings etc.
  • Page 18: Short Cut-Menu

    CVBS: Click icon “CVBS” to enter, you can test IP and analog camera at the same time. TV OUT: Click Video OUT to enter floating window, connecting the BNC cable to tester and appears analog video monitor interface, it can test circuit and BNC cable whether normal. LAN info: Display network port or WIFI connection real-time upload and download speeds and other network parameters.
  • Page 19: Screen Capture

    Press the key “ ”, you can turn on it and switch functions, then press to enter app, tap other area on the screen, to exit the menu Short cut-menu setting, you can long press any app in the all applications list, it will auto move to shortcut menu.
  • Page 20: Testerplay

    You can go file management to view “file management –SD card- Pictures—Screenshots”. 3.3.5 TesterPlay Mobile screen projection (Only for android version) The meter creates WIFI hotspot, connect mobile phone to the tester’s WIFI hotspot, or the tester and mobile phone connect to the same Wi-Fi network. Tap icon “ ”, then select “TesterPlay”...
  • Page 21: Rapid Video

    3.3.6 Rapid video Press enter function, one key to detect all network cameras and auto play the images Auto log in and display camera image. Detailed operation refer to ONVIF function - 16 -...
  • Page 22: Ip Discovery

    After exit ONVIF app, Click Refresh to search ip address. 3.3.7 IP discovery Press IP discovery , tester auto-scan the whole network segment IP, as well as auto-modify the tester’s IP to the same network segment with the scanned camera's IP. - 17 -...
  • Page 23: Rapid Onvif Test

    Local IP: Tester’s IP address, Tester can auto-modify the tester’s IP to the same network segment with the scanned camera's IP Discovery IP: Connected tester equipment’s IP address. If the camera connected to the tester directly, tester will display the camera’s IP address, if tester connects to Local Area Network, it displays the current IP address.
  • Page 24 If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List. Tester can auto login camera and display camera image. Click the button “Refresh”, tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the “Device List”.
  • Page 25 When comes out “activate success” prompt, click login to display camera image. Pop-up settings menu when click the “ONVIF setting” icon in the upper left corner Across network segments scan: After open this function, enter “Setting - IP Settings - Advanced ” to add other network segments IP, Rapid ONVIF function can across network segments to scan camera’s IP.
  • Page 26 Confirm : Save the modified parameters Click “MENU” icon to open camera setting. While in the “Live video” menu, click “Video Menu” at the top right of the image to access the following tools: Snapshot, Record, Photo, Playback, PTZ and Settings ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move.
  • Page 27 IP camera video settings: Click “Video Set” to enter the IP camera’s encoder and resolution settings. Make the desired changes and click “OK” to save. Image setting: Click “Imaging Set” to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. - 22 -...
  • Page 28 Profiles: Click “profiles”, can view video streaming current configuration files, as well as switch between Major stream and minor stream. Preview pictures: Quickly preview and zoom in or out pictures, automatically and manual refresh - 23 -...
  • Page 29 Identification: Click “Identification” to view information of the camera Time set: Click “Time set”, Select "Manual set" to set up the time of camera Maintenance: For camera software reset or restore to factory settings. - 24 -...
  • Page 30 User Set: Modify camera user name, password etc. parameters Network setting: Click “Network Set" to change the IP address. Some cameras cannot support change IP address, so there is no change after saving. Zoom in image: Press the key to enter the zoom mode. Press it again to exit zoom mode. When the image is enlarged tap left, right, up or down on the image to move the whole image on the screen - 25 -...
  • Page 31 When the image is enlarged, if not operate on touch screen, it can operate by the keyboard, press the to zoon in, press the key to zoom out, press upward and downward key to move image. If it is network video input to the tester, as the tester supports resolution up to 1080p, the input image will be very clear after it is enlarged.
  • Page 32 If select manual storage, appears dialog box “Input Name”, user-defined the files name (by Chinese character, English letter or digit) to save in SD card, if select “Auto- storage”, the tester auto stores the files after snapshot. Record: When you click bottom the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video.
  • Page 33 Video files can play in the Video player on the main menu. Set preset position: Move the camera to preset position, enter the preset number on the Bottom right corner to complete position preset. Call the preset position: Select the preset number on the left, click "Call" to call preset - 28 -...
  • Page 34 PTZ Speed set: Horizontal and Vertical Speed set RTSP: Get RTSP address of the current camera Doc: Auto generate test reports document of camera, click "Create document”. Click Preview to view the report document Enter the camera test information, click "Create Document" to complete the report. - 29 -...
  • Page 35: Ip Camera Test

    Click doc menu again, you can preview the report document. Icons description: the description of function icons on the bottom toolbar 3.3.9 IP camera test Display image from the 4K H.265 camera by mainstream Click icon to enter IP camera test Note: Currently, the IPC Test App only supports some brands specific IP cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more.
  • Page 36 Local IP: This is the tester’s IP address. Click “Edit” to enter “IP setting” and change the tester’s IP address settings IP camera type: Click on the IP Camera type to select the Manufacturer and model number of the integrated IP camera Manual: Click IP camera type, list Honeywell, Kodak, Tiandy, Aipu-waton, ACTi, WoshiDA IP camera etc.
  • Page 37 IP Camera's IP: Enter the IP camera’s IP address manually or click “Search” to auto-scan for the IP camera’s IP address. It is better to directly connect the IP camera to the tester so the search results will only display the camera’s IP address.
  • Page 38: Video Monitor Test

    Once you are viewing video on the IPC Test app, you will see the “Video Menu” icon on the top right. This button will give you access to Snapshot, Record, Photo, Playback, PTZ and Set. Please refer to the ONVIF section to use these functions.
  • Page 39 A. Protocol Use the up and down arrow keys to move the yellow cursor to the “protocol”, set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco-D, Samsung, Yaan, LiLin, CSR600, Panasonic, Sony-EVI etc. B. Port Click and move, to “port” Select the communication port for the PTZ camera controlling (RS485) C.
  • Page 40 the IPC tester can test. After setting the parameter, the tester can control the PTZ and lens To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ.
  • Page 41 (3) 4 x zoom image display and Video out When image input, press to enter “zoom”, press it again to quit. Using the touch screen to control PTZ camera movement: Tap left, right, upward or downward on the video image to move the PTZ camera in a desired direction. Stretch two fingers outward or inward on the touch screen to zoom the image in or out.
  • Page 42 (5) Video record When you click the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the “Record” icon again to stop recording and save the video file to the SD card.
  • Page 43 image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears. (7) Recorded video playback Click the “Playback” icon to view your recorded videos. Tap on the video file image you want to watch. - 38 -...
  • Page 44 To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu “Video Player". (8) Video level meter Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST Chroma level.
  • Page 45 While in PAL format, the unit will be mV, while in NTSC format, it will be IRE. Video signal level 140 ± 15IRE NTSC Chroma level (COLOR BURST) 40 ± 5IRE SYNC signal level 40 ± 5IRE Video signal level 1000 ±...
  • Page 46: Color-Bar Generator (Tv Out)

    COLOR BURST level: Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit. Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image. For NTSC format, the Chroma standard level is 40 IRE For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter.
  • Page 47: Cvi Camera Test (*Optional)

    display on the screen and output, click to return main menu. Application BNC loop test: Tester can send and receive color bar generator through the tester’s “video out and video in” port, it is for testing transmission channels, such as video Optical, video cables etc. The tester “VIDEO OUT” port to connect optical terminal’s sending port, and “VIDEO IN”...
  • Page 48 When HD CVI signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows 1280 x 720P 25FPS / 1280 x 720P 30FPS / 1280 x 720P 50FPS / 1280 x 720P 60FPS 1920 x 1080P 25FPS / 1920 x 1080P 30FPS / 2560 x 1440P 25FPS / 2560 x 1440P 30FPS.
  • Page 49 Enter PTZ address to perform parameters setting Operation instructions, please refer to “3.3.1 PTZ (1) Video monitor test”. The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test .After setting the parameter, the tester can control the PTZ and lens. - 44 -...
  • Page 50 To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ.
  • Page 51 Tap the preset position: Tap the preset position area, input preset position number. Tap “call position” to complete call preset position. - 46 -...
  • Page 52 1.2 RS485 control Operation instructions, please refer to “3.3.1 PTZ (1) PTZ control parameters setting”. (2)Coaxial camera menu setting Tap icon “UTC”, select “menu setting” to enter the dome camera menu Input calling dome camera menu address code, after finishing the parameter settings, you can press the key or click the icon to call the dome camera menu.
  • Page 53 Press arrow keys to set (3) Snapshot, record, photo viewer and video play back, please refer to “3.3.1 PTZ (1) Video monitor test”. Tap “close menu” or press the key “ ” to close camera menu - 48 -...
  • Page 54: Tvi Camera Test (*Optional)

    (4) Save setting Click icon “Set” on the right toolbar to enter storage setting. Support auto-storage and manual storage. When select manual storage, user can name and store the files. 3.3.13 TVI camera test (*Optional) HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter - 49 -...
  • Page 55 When HD TVI signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280 x 720P 25FPS / 1280 x 720P 30FPS / 1280 x 720P 50FPS / 1280 x 720P 60FPS 1920 x 1080P 25FPS / 1920 x 1080P 30FPS / 1920 x 1080P 50FPS / 1920 x 1080P 60FPS / 2048 x 1536P 18FPS / 2048 x 1536P 25FPS / 2048 x 1536P 30FPS / 2560 x 1440P 15 FPS / 2560 x 1440P 25 FPS / 2560 x 1440P 30 FPS / 2688 x 1520P 15FPS / 2592 x 1944P 12.5FPS / 2592 x 1944P 20FPS...
  • Page 56: Ahd Camera Test (*Optional)

    Input calling dome camera menu address code, after finishing the parameter settings, you can press the key or click the icon to call the dome camera menu. More operation instructions (such as PTZ control, coaxial camera menu setting, snapshot, recording and playback etc.), please refer to “3.3.6 CVI camera test”.
  • Page 57 When AHD signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280 x 720P 25FPS / 1280 x 720P 30FPS / 1920 x 1080P 25FPS / 1920 x 1080P 30FPS / 2048 x 1536P 18FPS / 2048 x 1536P 25FPS / 2048 x 1536P 30FPS / 2560 x 1440P 15 FPS / 2560 x 1440P 25 FPS / 2560 x 1440P 30 FPS / 2592 x 1944P 12.5FPS / 2592 x 1944P 20FPS (1) Coaxial PTZ control...
  • Page 58: Network Tool

    If to coaxial PTZ control the AHD camera, no parameters setting is needed. More operation instructions please refer to “3.3.6 CVI camera test” 3.3.15 Network tool (1)IP address scan Connect the cable to the LAN port, click icon to enter, Set your IP address search range by changing the Start and End IP addresses.
  • Page 59: 2)Ping Test

    (2)PING Test Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet time and Timeout.
  • Page 60 a). Start the server: Click “Start Server” button to use the tester as a Server. It will display its IP address at the top of the screen. b). Start send packet test: Using the other IP tester, type in the Server's IP address at the top right corner of the screen.
  • Page 61 Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If use computer as the server, the computer IP address is: 192.168.0.39 Tester as Client, tester’s IP address is: 192.168.0.238.
  • Page 62 Or use tester as a Server, computer as test Client(select Client, input tester’s IP address to test) When use tester as Server, shows results: - 57 -...
  • Page 63: 4)Port Flashing

    (4)Port Flashing Connect a network cable to the meter’s “LAN” port, click the icon to open the Port Flashing app. Click “Start”, the IP tester sends a unique signal to make the connected LAN port of the switch flash. If the tester and PoE switch are connected well, the LAN port of POE switch flash at special frequency, if not, no any changes on the LAN port Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will...
  • Page 64: 5)Dhcp Server

    (5)DHCP server Click on the DHCP icon to open the DHCP server app. Select the “Start” check box at the top and make any desired changes to the network settings. Click “Save” to start assigning dynamic IP addresses for IP cameras and other networked devices.
  • Page 65: 7)Link Monitor

    Click “start” to trace the goal address (7)Link monitor Click the icon to open the Link Monitor app. This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts Click “Add”...
  • Page 66: Rapid Ip Discovery

    Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will result IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.16 Rapid IP Discovery Connect the cable to tester’s LAN port.
  • Page 67: Cable Test

    Note: 1. Don’t input power into the “DC12/2A OUTPUT” port. 2. Don’t output this DC12V/2A power to the DC12V/IN port of the IP camera tester to avoid destroy 3. The IPC tester power output is close to 2A, if the IP camera’s power is over 2V, the tester will auto enter protection mode.
  • Page 68: Rj45 Cable Tdr Test

    connecting status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed. The number of the cable tester is 255 If need several different number other types cable testers, should pay the additional cost. Tap "cable test sketch map", pop up Straight-through cable and crossover cable sketch, It is for line sequence reference, when the crystal on the first pressure in the twisted-pair.
  • Page 69 Single test: Test cable status, length and attenuation. Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display “online”, if not link up or open circuit, screen display ”open circuit”, if cable pair is short circuit, screen display “short circuit”. Length: The max test length is 180 meters, when cable is open circuit or short circuit, can test the cable length, if screen display “online”, the testing result would be not accurate.
  • Page 70 Cable sequence diagram: A straight- through and cross-over cable diagram, the cable sequence display for reference Click “Help”, check the instruction of all parameters. - 65 -...
  • Page 71: Cable Tracer (*Optional)

    3.3.20 Cable Tracer (*Optional) Connect test cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. Use the blue Combination cable identifier and network cable tester’s copper pointer to touch all the cables in the bundle .
  • Page 72: Tdr Cable Test (*Optional)

    Note: The battery of the cable tracer must according to corresponding positive pole + and negative pole -, otherwise will damage the tester. Note: While the cable tracer tester is receiving the audio signal from the tester, it may be influenced by other signals and make some noise.
  • Page 73 User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click “Cable”, “Type” to select user-defined 1 for calibration, 11 groups user-defined can be set. 1 .Select user-defined and click “Calibration” to enter test, click “user-defined 1” can define cable name, such as: AiPu BNC-5 2.
  • Page 74 3. Click “+”or “-” to adjust wave speed, while display length is the same with the actual Length, click “Save” to save calibration data. It can be used for the same cable testing next time. Application: TDR test is the use of pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen.
  • Page 75: Poe Voltage Test

    3.3.22 PoE Voltage test Click icon to enter PoE voltage measurement Connect a network cable from a PoE switch to the IP tester’s PSE IN port. Connect an IP camera or other PoE using node to IP tester’s LAN port, the PoE voltage and the cable’s pin connection status show on the screen. Note: This test is for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work.
  • Page 76: Digital Multi-Meter (*Optional)

    Connect 12V power adaptor to tester’s charging port, then click icon “PoE” to enter voltage measurement app, screen show the current adaptor input voltage and power. Note: the current 12V input measured power is the battery charging power and the device working power, the measured power will change depending on the different of battery power and backlight brightness.
  • Page 77 1) SYMBOLS: U: DC Voltage Measuring A: DC Current Measuring Ω: Resistance Measuring : Diode Testing : AC Voltage Measuring : AC Current Measuring : Continuity Testing : Capacitance Measuring AC/DC Voltage and current measurement state display Auto- range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative...
  • Page 78 Manual range: 0.000V → 6.600V range 00.00V → 66.00V range 000.0V → 660.0V range 000.0mV → 660.0mV rang B. AC Voltage Measuring WARNING! You can’t input the voltage which more than 660V AC, it’s possible to show higher voltage, but it’s may destroy the inner circuit.
  • Page 79 c.Manual range: 0.000mA → 6.6mA range 00.00mA → 66.00mA range 000.0mA → 660.0mA range → 10.00A range(use 10A socket) 00.00A d. Select the range to enter current measurement NOTE: ◆ When only the figure “OL” is displayed, it indicates over range situation and the higher range has to be selected.
  • Page 80 → 10.00A range(use 10A socket) 00.00A NOTE: ◆ When only the figure “OL” is displayed, it indicates over range situation and the higher range has to be selected. ◆ When the value scale to be measured is unknown beforehand, set the range selector at the highest position.
  • Page 81 00.00 MΩ → 66.00MΩ range F. Continuity Testing WARNING! When testing the circuit continuity, be sure that the power of the circuit has been shut down and all capacitors have been discharged fully. a. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack. b.
  • Page 82 press the key “NEAR” → Manual range: 0.000nF 6.600nF range → 00.00nF 66.00nF range → 000.0nF 660.0nF range → 0.000uF 6.600μF range → 00.00uF 66.00μF range → 000.0uF 660.0μF range → 0.000mF 6.600mF range → 00.00mF 66.00mF range d. Before connect test leads across two sides of the capacitor under measurement, be sure that the capacitor has been discharged fully.
  • Page 83: Optical Power Meter (*Optional)

    Data hold Click “Hold data” to enter, the data be hold, the value is green. Press it again to quit. Relative value measurement Click “Relative” to enter, the tester Auto-save the data, the displayed new measurement and relative value is red color. Press it again to quit The hold function and the relative value be combined use, the display value is yellow The meter protection ➢...
  • Page 84 Data hold While testing, click “Hold” to data hold, the data will not change. It’s convenient to read. Press again to quit. Relative power value (optical link loss) measurement While testing, set the wavelength for measurement. Click “relative” (difference) to test, the tester Auto save current fiber power value as the base reference value.
  • Page 85: Visual Fault Locator (*Optional)

    Data hold and Relative measuring use together, the data is yellow while the function is effect. 3.3.26 Visual Fault Locator (*Optional) Click icon to enter VFL four status can select——“Steady mode”, “Evasive 1Hz”, “Evasive 2Hz” and “Time off”. Click button “Steady mode”...
  • Page 86: Audio Record

    Click “Steady mode”, red laser source emits steady, click again to quit. Click icons “Evasive 1Hz” or “Evasive 2Hz” to enter pulse mode, the red laser source is emitted by a certain frequency, press it again to quit. 3.3.27 Audio Record Connect an audio device to the IP tester’s audio input port.
  • Page 87: Data Monitor

    3.3.28 Data monitor Please click icon to enter Click “Setting” to choose the baud rate of RS485; it must be the same as the DVR or the Control keyboard .The DVR or Control keyboard send the code to the tester, if it can be read, the protocol will show on the upper right, like Pelco D, if not, like P:--- While the tester receives the code, press the key to empty.
  • Page 88: Audio Player

    3.3.29 Audio player Click the icon to enter. The audio player only supports MP3 format Audio files. 3.3.30 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4 and MKV.
  • Page 89: Rtsp Player

    3.3.31 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video.
  • Page 90: Hik Test Tool

    network for cameras that use an RTSP stream. IPC Username: Enter the IP camera’s user name. IPC Password: Enter the IP camera’s password. Once you have entered all the necessary information, select Enter at the bottom left to view the RTSP stream. Note: in the event the IP tester does not auto detect the RTSP stream, refer to the specific camera manufacturer for the specific RTSP stream URL.
  • Page 91 2. Input password: Input new password, tap “ok” to activate 3. Confirm activation After activating the camera, the program default modifies the camera IP. Activated multiple cameras in the local area Network, and pop-up menu to modify IP, improve project efficiency. - 86 -...
  • Page 92 Play: Display image from the camera Modify network information: Change the camera IP address, subnet mask and gateway etc. Modify user information: Modify the camera's user name and password. Factory Reset: Camera factory reset - 87 -...
  • Page 93: Dahua Test Tool

    3.3.33 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, and modify IP, user name and password etc. Making Dahua camera test more convenient and quickly. Click “DH” icon to enter Dahua test tool.
  • Page 94 If the camera not supports non-verification login, please select “camera” of online detection menu, and input correct user name and password, then click “log in”. After logging successful, you can test it. Play: Select mainstream or seconded stream, IP camera live video display Modify network information: modify camera parameter, such as IP address, subnet mask, gateway etc.
  • Page 95 Modify user information: Modify camera user name and password, which is ONVIF, Dahua test tool, IPC TESTE user name and password, not web user name and password. Factory reset setting: Camera will be soft reset, and the device’s user name, password and network set be saved.
  • Page 96: Update

    3.3.34 Update Copy the downloaded update file to SD card "update" directory, if no directory exists, please create one. Click the Application Update icon to open the Update menu. Select “Local Update” to update via the SD card or select “Online Update” to check for updates on the internet. If there are applications that need updating, the applications will be displayed on the main area to the right of the update buttons.
  • Page 97: Office

    3.3.35 Office Quick office app (support excel, word, ppt format) doc. editable 3.3.36 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon to enter. While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don’t press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on.
  • Page 98: Browser

    3.3.37 Browser Click icon to enter Type in the camera’s IP address and press “Go” to access the IP camera’s interface. NOTE: You will not be able to view live video in the web browser. For viewing video, use the IP tester’s live camera view Apps The IP camera and IP tester be on the same network segment for the browser to interface with the camera.
  • Page 99: System Setting

    Please click to view the notepad, all saving contents display. Click each record bar to show the details. Press the record bar for several seconds, prompt whether delete it 3.3.39 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish, Spanish, French or Japanese Typewriting: You can select typewriting or install other typewriting: Date/Time: Set the Date/time of the IP tester...
  • Page 100 allocation” to use DHCP. WLAN Net: Turn WIFI off or on by pressing the “Open the wifi” button. Once WIFI is turned on, and click connected WIFI, it will scan for wireless networks in your area. Select and press “WIFI” several seconds, to set static IP address - 95 -...
  • Page 101 Wi-Fi hotspot: Input “SSID” name and “password”, and then click “ok” to create wifi hotspot. Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing it. FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files via FTP Start the FTP server and then input the tester’s FTP address in the PC’s address bar.
  • Page 102: File Explorer

    Version information: Shows applications version information, if press any apps icon several seconds to uninstall Screen display rotation: Click on “Screen Rotation” to flip the IP tester’s display 180 degrees. This function is very convenient for the user to connect the LAN cable on the bottom of the unit without having to flip the unit itself.
  • Page 103 Browse It includes Music, Videos, Pictures, Documents, zip file etc. It is convenient to view and manage FTP server You can choose internal or external SD card. Other operation details, please refer to FTP settings - 98 -...
  • Page 104: Theme

    3.3.41 Theme Click Theme icon to enter themes setting. Desktop style: you can select Lite mode or normal mode. Theme: Pressing square area’s any color icon several seconds, the selected color icon will be auto move the rectangle area, if you press selected color several seconds, and it will be auto deleted Theme colors include fixed order and random order, and click “set”...
  • Page 105 Set as desktop background: Setting color as desktop background Set as application background: Set color as application background Set at the same time: Setting color as desktop background and application background. Cancel: Cancel current setting. Picture: Click Picture to select one, and set as temporarily background to view setting effect. Click “more” to select pictures from local file, and click set to set picture as background.
  • Page 106: Audio Test

    Sliding effect: Tester’s sliding effect includes stereo effect, folding effect, Left and right folding, rotate effect, Ombre effect etc., selecting one of effect to view slide effect in the square area, and click “set” to save 3.4 Audio test You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable.
  • Page 107: Dc12V 2A Power Output

    The IP tester supports PoE (Power over Ethernet) output to an IP camera via the LAN port. Data transmission and 48VDC use the network cable’s 1, 2, 3, and 6 pins to deliver power. If the IP camera supports PoE, you can directly connect to the camera without the use of an external power supply.
  • Page 108 Application Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some camera installation sites, if there is no power outlet for the adapter to power the camera, the tester can offer temporary power for it. But we do not suggest tester supply power for a long time. Notice: Don’t input any power into the “DC12/2A OUTPUT”...
  • Page 109: Specifications

    Dahua Camera Test, Modify IP addresses, Modify Username and Password, Dahua Test Tool Parameters, etc. ONVIF, ONVIF PTZ , Opticom, Dahua IP Cameras, Hikvision IP Cameras, Samsung Supported IP Camera IP Cameras, Tiandy IP Cameras, Kodak IP Cameras, Honeywell IP Cameras, RTSP...
  • Page 110 Control for OSD 1 Channel AHD Input - BNC interface, Resolution Support of up to 5MP, 2592 x 1944p @ 12.5/20fps, 2560 x 1440p @ 15/25/30fps, 2560 x 1440p @ AHD Capabilities 15/25/30fps, 2048x1536p @ 18/25/30fps, 1080p @ 25/30fps, 720p @ 25/30fps, UTC Control for OSD Analog/CVBS 1 Channel BNC Input &...
  • Page 111: Multi-Meter Specifications

    Cable tracer Find a connected cable from a bundle of cables using audio tones *(Optional) PoE/PSE voltage test Measures PoE switch voltage and displays pin configuration AC/DC Voltage, AC/DC current, Resistance, Capacitance, Data hold, Relative Digital Multi-meter measurement, Continuity testing. Testing speed: 3 times/ seconds, Data range *(Optional) -6600 ~ +6600.
  • Page 112 Conversion rate: 3times/s Current modes for clamp meter with ZERO function Isolation: the Multi-meter connector must be isolated with the other connector. DC voltage Range Accuracy Resolution 660mV (Manual range) 0.1mV 6.600V ±(0.3%+4) 66.00V 10mV 660.0V 100mV AC voltage Range Accuracy Resolution 660.0mV (Manual range)
  • Page 113 66.00mA 10uA 660.0mA 100uA 10.00A 10mA ±(1%+5) Resistance Range Accuracy Resolution 660.0Ω 0.1Ω ±(0.8%+5) 6.600KΩ 1Ω 66.00KΩ 10Ω ±(0.8%+2) 660.0KΩ 100Ω 6.600MΩ 1KΩ 66MΩ ±(1.2%+5) 10KΩ Continuity Range Resolution Function 660.0Ω 0.1Ω The measurement value less 30Ω±3Ω,the tester will sound Diode Range Resolution...
  • Page 114: Optical Power Meter Specifications

    660.0nF 100pF 6.600μF 66.00μF 10nF 660.0μF 100nF 6.600mF 1μF ±(5%+8) 66.00mF 10μF 4.3 Optical power meter specifications Measure Range(dBm) -70 ~ +10dBm Wavelength(nm) 850nm,1300nm,1310nm,1490nm,1550nm,1625nm Detector InGaAs <±3%dB (-10dBm, 22℃) <±5%dB (full range, 22℃) Uncertainly Display Resolution Linear: 0.1%; Nonlinear: 0.01dBm Operating Temperature (℃) -10 ~ +50 Storage Temperature (℃)
  • Page 115 Modulation mode CW / 1Hz / 2Hz Measurement Range 5KM (Optional 10 ~ 20KM) Connector FC / PC exchangeable Working Temperature -10℃ ~ +50℃ Operating Temperature -20℃ ~ +70℃ The data above is only for reference and any change of them will not be informed in advance. For more detailed technical inquiries, please feel free to call the Technical Department of our company.

Table of Contents