Advertisement

Installing the boiler
Electrical connections
Connections to 230 V~ plugs
Power supply
Power supply for accessories
lH
External demand/blocking
Connections to LV plugs
X3
Plug X3 can be removed to facilitate installation.

Outside temperature sensor

!
Flow temperature sensor for low loss header
?
(accessories)
X4
KM-BUS connection, variable speed heating cir-
cuit pump (if installed)
X21 CO limiter (accessories)
KM-BUS subscriber (accessories)
aVG
To connect several accessories, see page 21.
Vitotrol 200-A or 300-A remote control unit
Vitocom 100, type GSM
Mixer extension kit
AM1 extension
EA1 extension
Wireless base station
KM-BUS distributor
Outside temperature sensor
Fitting location for outside temperature sensor
North or north-westerly wall, 2 to 2.5 m above
ground level; in multi storey buildings, in the upper
half of the second floor
Not above windows, doors or vents
18
(cont.)
!
Information on connecting accessories
When connecting accessories observe the sep-
arate installation instructions provided with
them.
Not immediately below balconies or gutters
Never render over.
Outside temperature sensor connection
2-core lead, length max. 35 m with a cross-section of
1.5 mm
2