Maintenance; Putting The Control Unit Into The Service Position; Draining The Boiler On The Heating Water Side - Viessmann Vitodens 222-F Installation And Service Instructions For Contractors

Gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

Troubleshooting

Maintenance

Putting the control unit into the service position

If required for commissioning and servicing, the control
unit can be put into a different position.
Fig. 54

Draining the boiler on the heating water side

!
Please note
Risk of scalding
Residual water will escape when the boiler or
one of the following components is fitted or
removed:
Water-filled pipework
Circulation pumps
Plate heat exchanger
Components fitted in the heating water or
DHW circuit.
Water ingress can result in damage to other
components.
Protect the following components against
ingress of water:
Control unit (in particular in the service posi-
tion)
Electrical components
Plug-in connections
Cables and leads
Only drain the boiler or heating system when the
boiler water or cylinder temperature has drop-
ped below 40 °C.
96
2.
3.
1.