Viessmann Vitodens 222-F Installation And Service Instructions For Contractors page 59

Gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

Heating circuit 1, heating circuit 2, heating...
"Heating limit: Complete summer economy control"
Setting
None
... °C
"Mixer economy function"
Setting
Without
With
"Pump idle time"
Setting
With calculated pump idle time
Without
With calculated pump idle time
"Room temperature hook-up"
Setting
Without
For reduced mode
For standard mode
For standard mode and reduced mode
"Economy function room temperature"
Setting
Without
... see service instructions
(cont.)
Explanations
A6:36
Extended economy function disabled
A6:5 to
Extended economy function enabled: The burner and
A6:35
heating circuit pump will stop at a variable value, ad-
justable between 5 and 35 °C plus 1 °C. The mixer
closes.
The basis for this is the adjusted outside temperature.
This is based on the actual outside temperature and a
time constant, which takes into account the cooling
down of an average building.
Explanations
A7:0
A7:1
Heating circuit pump also "OFF":
If the mixer has been trying to close for some time.
Heating circuit pump "ON":
If the mixer changes to control function
If there is a risk of frost
Explanations
A9:7
Heating circuit pump "OFF" if set value is modified by
changing the operating mode or changing the set
room temperature.
Only if room hook-up is not set in parameter b0.
A9:0
No economy function outside temperature
A9:1 to
Adjustable from 1 to 15. The higher the value, the lon-
A9:15
ger the pump idle time.
Explanations
B0:0
With remote control: heating mode/reduced mode:
weather-compensated
Change value only for the heating circuit with mixer.
B0:1
Heating mode: weather-compensated
Reduced mode: with room temperature hook-up
B0:2
Heating mode: with room temperature hook-up
Reduced mode: weather-compensated
B0:3
Heating mode/reduced mode: with room temperature
hook-up
Explanations
B5:0
With remote control: no room temperature-dependent
economy function.
Change value only for the heating circuit with mixer.
B5:1 to
For economy function, see the following table:
B5:8
Parameter level 1
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2sb