Viessmann Vitodens 222-F Installation And Service Instructions For Contractors page 67

Gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

General
(cont.)
"Flow temperature sensor for low loss header"
Setting
Without
With
"Function, output, internal connection extension"
Setting
Central fault
DHW circulation pump
Heating circuit pump A1
Circulation pump for cylinder heating
"Solar thermal system"
Setting
Without
With Vitosolic 100
With Vitosolic 200
With solar control module, type SM1, with-
out auxiliary function; automatic recognition
With solar control module, type SM1, with
auxiliary function, e.g. central heating back-
up; automatic recognition
"Display correction for outside temperature"
Setting
... K
None
... K
"Communication module"
Setting
Without
With LON communication module
With cascade communication module
"LON subscriber number"
Setting
LON subscriber number
Explanations
52:0
52:1
Automatic recognition
Explanations
Actuator at terminal
53:0
53:1
53:2
Circulation pump for heating circuit without mixer
53:3
Circulation pump/diverter valve for DHW heating
Explanations
54:0
Do not adjust in the case of storage combi boilers
without solar DHW heating.
54:1
54:2
54:3
54:4
2nd differential temperature control with temperature
sensor
/
and
Explanations
6E:0 to
Display correction -5 K to -0.1 K
6E:49
6E:50
6E:51 to
Display correction +0.1 K to +5 K
6E:100
Explanations
76:0
76:1
Automatic recognition
76:2
Do not adjust
Explanations
77:1
77:2 to
Adjustable from 1 to 99:
77:99
1 = Boiler
10 to 90 = Vitotronic 200-H
97 = Vitogate 300 BN/MB
98 = Vitogate
99 = Vitocom
Note
Allocate each number only once.
Parameter level 2
sK
67