Siting the cylinder
!
Please note
Exposure to frost can damage the appliance.
Install the buffer cylinder in a room that is free
from the risk of frost and draughts. Otherwise,
the buffer cylinder must be drained if there is a
risk of frost while it is not in use.
Provide adequate clearance from the wall to allow for
operation of the temperature controller (if installed).
Placing the heating water buffer cylinder on a plinth
will make the room easier to clean.
Use adjustable feet to level the buffer cylinder.

Fitting the lower thermal insulation mat and aligning the cylinder body

1.
A
2.
B
Fig. 1
Bag containing type plate
A
Bag containing 3 adjustable feet
B
3. Insert the adjustable feet into the supports as far
as they will go, then adjust them to level the cylin-
der body.
Note
Never extend the adjustable feet beyond a total
length of 35 mm.
!
4.
3.
3x
Installation sequence
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
7