Bmc Self Recovery - Inspur NF8480M5 User Manual

Table of Contents

Advertisement

9.11.3 BMC Watchdog for System
Software watchdog can be used for a number of system timeout function by system
management or by BIOS. If software watchdog is triggered, the following actions are
available.
System Reset
System Power Off
System Power Cycle
When BMC watchdog working, BMC will record SEL log.
9.11.4 BMC Recovery
Users can reset BMC from WEB or IPMI interface in case of abnormal situation.
Warm reset BMC, use "ipmitool mc reset warm", IPMI Server, KVM Server, WEB Server
will be reset.
Cold reset BMC, use WEB or "ipmtool mc reset cold", BMC will be reset.
KVM reset, user WEB and KVM server will be reset.
Figure 34 BMC Recovery

9.12 BMC Self Recovery

BMC Self Recovery provides the ability of automatic repair operations as well if necessary.
9.12.1 Hardware Watchdog
Known fault scenarios:
Kernel panic
System resources exhausted or error, system can't create a new task, but the original
task can continue to run.
Hardware watchdog:
Watchdog starts when uboot loads kernel, and the timeout is 5 minutes. If BMC boot
timeout occurs, BMC will reset.
After the BMC system starts, the main process resets the Watchdog every minute. If the
108