Installation
(continued)
5 . Connect water line . Recommended routing (Fig . 3) allows easy access
to water for cleaning and sanitizing procedure .
6 . If installing the optional internal water filter*, please complete the
steps shown in
Cleaning and Sanitizing on page 11
proceeding . If not, proceed to step 10 .
* If your dispenser has the internal water filter option, the water filter must be
installed for the dispenser to operate . Because internal components will need to
be accessed for both procedures, Follett recommends installing the water filter
just prior to initial sanitizing .
7 .
Lift and remove the top panel, set aside (Fig . 4 .1) .
8 . Remove two screws (Fig . 4 .2) and remove left side panel .
9 . Install filter as shown . Turn filter clockwise until it is fully seated
(Fig . 4 .3) .
10 . Connect power supply .
11 . Sanitize the dispenser prior to use (see
on page
11) .
8
Undercounter Dispenser and Ice machine 7UC100A/7UD100A
–––––––––––––––––––––––––––––––––––––––––––––––––
Cleaning and Sanitizing
Fig . 3
3' (91.4 cm)
Fig . 4
before
2
Plug
Valve
1/4" MPT
1
3