Zero Phase Reactor

Zero - phase reactor should match wire gauge. *
*
Current values for wire gauges may vary based on electrical codes.
The table below lists selections based on Japanese electrical standards rating.
Contact Yaskawa for questions regarding UL.
Pass each wire ( U/T 1 , V/T 2 , W/T 3 ) through the core 4 times. Noise will be more
effectively reduced when more wire is wrapped.
If the wire is thick and cannot be wrapped around the core, pass it through in
series of no less than 4 cores.
Connection Diagram
Compatible with the input and output side of the drive.
Example : Connection to
Enlarged view of
V/T 2 - phase wiring
output terminal
Drive
Zero phase reactor
R/L 1
U/T 1
S/L 2
V/T 2
M
T/L 3
W/T 3
Pass each wire ( U/T 1 , V/T 2 , W/T 3 )
through the core 4 times.
Diagram a
Dimensions ( mm )
Hex
socket
× 3
( M 4 )
4 . 5 dia. × 3
50 ± 1
95 max.
80 ± 1
5 . 5 dia. × 2
Model F 6045 GB
200 V Class
CR 700
Motor
Recommended
Input Side
Capacity
Gauge ( mm
2
)
( kW )
Input
Output
Model
Code No. Qty. Diagram
Side
Side
0 . 4
0 . 75
2
2
F 6045 GB
FIL 001098
1 . 5
2 . 2
3
3 . 5
2
F 6045 GB
FIL 001098
3 . 7
3 . 5
3 . 5
5 . 5
8
3 . 5
F 11080 GB
FIL 001097
7 . 5
14
8
F 6045 GB
FIL 001098
11
14
14
15
22
14
F 6045 GB
FIL 001098
18 . 5
38
22
22
50
30
F 11080 GB
FIL 001097
30
38
38
F 6045 GB
FIL 001098
37
60
60
45
80
80
F 11080 GB
FIL 001097
55
100
125
75
60
×
2 P 50
×
2 P F 200160 PB 300-001-041
90
80
×
2 P 80
×
2 P
F 200160 PB 300-001-041
110
125
2 P 125
2 P
×
×
Depending on the loading conditions of the motor, when a wire is
selected that is not of the recommended gauge, select a zero - phase
reactor using the table below.
Wiring Gauge Guide mm
2
2 to 5 . 5 or less
More than 5 . 5 to 8
More than 8 to 38
× 2
More than 38 to 200 , more than 38
P to 50
× 2
More than 200 to 250 , more than 50
P to 150
× 4
× 8
More than 150
P to 150
P
Drive
1 st pass
R/L 1
U/T 1
2 nd pass
S/L 2
V/T 2
T/L 3
W/T 3
3 rd pass
4 th pass
All wires ( U/T 1 , V/T 2 , W/T 3 ) should pass
through the four cores of the reactor in
series without winding.
26 max.
100 ± 1
181 max.
150 ± 1
Weight : 195 g
Model F 11080 GB
Zero Phase Reactor
Output Side
Model
Code No. Qty. Diagram
1
a
F 6045 GB
FIL 001098
1
a
1
a
F 6045 GB
FIL 001098
1
a
1
a
F 6045 GB
FIL 001098
1
a
4
b
F 11080 GB
FIL 001097
1
a
4
b
F 6045 GB
FIL 001098
4
b
4
b
F 6045 GB
FIL 001098
4
b
4
b
F 6045 GB
FIL 001098
4
b
4
b
F 11080 GB
FIL 001097
4
b
4
b
F 11080 GB
FIL 001097
4
b
4
b
F 200160 PB 300-001-041
4
b
Model
Code No.
Qty. Diagram
F 6045 GB
FIL 001098
1
a
F 11080 GB
FIL 001097
1
4 *
F 6045 GB
FIL 001098
× 2
4 *
F 11080 GB
FIL 001097
P
b
× 4
P F 200160 PB 300-001-041 4 *
F 200160 PB 300-001-041 8 *
c
FINEMET Zero - Phase Reactor to Reduce Radio Noise
Zero phase reactor
M
Separate each terminal lead for U/T 1 , V/T 2 ,
and W/T 3 in half, passing one half of the wires
through a set of four cores and the other half
through the other set of four cores as shown.
Diagram b
Hex
socket
× 3
( M 5 )
26 max.
5 . 2 dia. × 3
12
Weight : 620 g
400 V Class
CR 700
Motor
Recommended
Input Side
Capacity
Gauge ( mm
2
)
( kW )
Input
Output
Model
Code No. Qty. Diagram
Side
Side
0 . 4
0 . 75
1 . 5
2 . 2
2
2
F 6045 GB
FIL 001098
3
3 . 7
5 . 5
7 . 5
3 . 5
3 . 5
F 6045 GB
FIL 001098
11
8
5 . 5
F 11080 GB
FIL 001097
15
14
8
F 6045 GB
FIL 001098
18 . 5
22
14
14
F 6045 GB
FIL 001098
30
37
22
22
45
30
30
F 6045 GB
FIL 001098
55
38
38
75
60
60
F 11080 GB
FIL 001097
90
80
80
110
50
×
2 P 50
×
2 P F 11080 GB
FIL 001097
132
160
80
×
2 P 80
×
2 P F 200160 PB 300-001-041
200
125
×
125
×
F 200160 PB 300-001-041
2 P
2 P
220
250
125
100
×
×
F 200160 PB 300-001-041
4 P
4 P
315
*
The selection of 4 or more zero - phase reactors assumes that the wires are thick
and cannot be wrapped.
When the wires can be wrapped, you can reduce the number of reactors used.
YASKAWA AC Drive CR700 Catalog
Hitachi Metals, Ltd.
Note : FINEMET is a trademark of
Hitachi Metals, Ltd.
Drive
Zero phase reactor
R/L 1
U/T 1
S/L 2
V/T 2
T/L 3
W/T 3
Diagram c
42 max.
241 max.
220 ± 0 . 5 max.
Weight : 2260 g
14
Model F 200160 PB
Zero Phase Reactor
Output Side
Model
Code No. Qty. Diagram
1
a
F 6045 GB
FIL 001098
1
1
a
F 6045 GB
FIL 001098
1
1
a
F 6045 GB
FIL 001098
1
4
b
F 11080 GB
FIL 001097
1
4
b
F 6045 GB
FIL 001098
4
4
b
F 6045 GB
FIL 001098
4
4
F 11080 GB
FIL 001097
4
b
4
b
F 11080 GB
FIL 001097
4
4
b
F 200160 PB 300-001-041
4
4
F 200160 PB 300-001-041
4
b
4
b
F 200160 PB 300-001-041
4
YASKAWA
KAEP C710617 24
M
a
a
a
a
b
b
b
b
b
b
b
43

Advertisement

Table of Contents
loading

Table of Contents