Technical Data
Supply voltage
Switch
Rated current
Maximum load
Operating temperature range
Thermostat adjustment range
Floor max. limitation range
Floor min. limitation range
Floor sensor
Sensor resistance values
Fuse
Ingress Protection
Pollution degree rating
Rated impulse voltage
Power in standby
Radio frequency range
Radio max. power
Dimensions WxHxD
13.
Accessories
ECOAC2
LS994BWWFI
LS981WW85FI
26 / 64
230 V -15%, +10%, 50 Hz
Not on the device, a separate main switch
must be installed
16 A
3600 W
-20 ... +30 °C
5 ... 35 °C room
5 ... 50 °C floor
+25 ... +50 °C
+5 ... +40 °C
NTC, 47 kΩ/25°C, cable 4 m
(extendable to 25 m)
Table 1, on page 2 (sensor not connected)
Max. 16 A
IP20
2
4 kV
< 0,5 W
2,4 ... 2,483 GHz
+3 dBm
36 x 90 x 58 mm
Room sensor: NTC, 47 kΩ/25°C, cable 4m
(extendable to 25 m)
Blank centre plate, white
Cover frame, 85mm, white
RAK128 / 10.6.2021