Step 3 Connect Ductwork; Step 4 Connect Electrical; Step 5 Install Duct Covers - Monogram ZV48SSJSS Installation Instructions Manual

Professional vent hood
Hide thumbs Also See for ZV48SSJSS:
Table of Contents

Advertisement

STEP 3 CONNECT DUCTWORK

airflow as illustrated.
• Secure joints in ductwork with sheetmetal screws.
seal.
• Use duct tape to seal the flange connection. Reach
inside the hood and push the damper up to be sure
it moves freely.
Duct Tape
Over Seam
and Screw
Duct Tape
Over Transition

STEP 4 CONNECT ELECTRICAL

Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
aluminum-to-copper connectors.
AVERTISSEMENT
de terre doit être ajouté par l'installateur. Lorsque le câblage
approuvés U.L.
ADVERTENCIA
conectores de aluminio a cobre aprobados por U.L.
• Use wire nuts to
connect incoming
to white and black to
black.
Be sure wires are not
pinched.
14
Installation Instructions
Air Flow
Screw
Si le câblage électrique de la
Si el cableado del hogar no tiene
A
B
Remove
Insert Power
Junction Box
Conduit Thru
Cover
Strain Relief
and Tighten
Ground
C
Use UL Listed
Wire Nuts

STEP 5 INSTALL DUCT COVERS

NOTE:
after film is peeled off.
Remove protective film from duct covers. If more than
with screws provided.
the covers.
White
Black
31-2000859 Rev. 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZV48SSJSS and is the answer not in the manual?

This manual is also suitable for:

Zv36ssjss

Table of Contents