Technical data

3. TECHNICAL DATA
3.1. DIFFERENCES BETWEEN
MODELS
Variations in technical design between models
K1260 and K1270 are described below:
PLACEMENT OF THE DECOMPRESSION VALVE
K1260
The decompression valve is located on the right
hand side of the cylinder.
K1270
The decompression valve is located on top of the
cylinder.
CYLINDER
K1260
Model K1260 is equipped with a chill casted
cylinder with integrated scavenging port.
K1270
Model K1270 is equipped with a die cast cylinder
with lids.
INLET MANIFOLD
K1260
After dismantling the carburettor the inlet manifold
can be removed.
K1270
The cylinder has to be dismantled before the inlet
manifold can be removed.
8
- English
K1260
DECOMPRESSION VALVE FOR K1270 AND K1260
K1270
CYLINDER FOR K1270 AND K1260
K1270
INLET MANIFOLD FOR K1270 AND K1260
K1270
K1260