To Shut Down - Flagro FV-200RC Series Operating Instructions Manual

Indirect fired space heaters
Table of Contents

Advertisement

1.
Move toggle switch to "OFF" position. Do not disconnect power supply
until the heat exchanger cools down
NOTE:
Fan will continue to operate after the burner shuts down. Once the
unit cools down, the fan will stop.
IF HEATER FAILS TO START:
1.
Press manual reset button at rear of burner.
2.
Check fuel level. There must be 2-4 gallons of fuel in the tank for the
heater to start properly.
3.
Make sure there are no air locks in fuel lines or filter.
4.
Ensure proper power supply and extension cord is being used.
5.
Check for dirty fuel filter or blocked fuel supply line.
6.
Check burner nozzle assembly.
NOTE:
IF THE BURNER HAS BEEN RESET SEVERAL TIMES THERE
MAY BE AN ACCUMULATION OF OIL IN THE CHAMBER!
CONTINUE TO TRY AND START THE HEATER!
DRAIN OIL FROM HEAT EXCHANGER USING DRAIN HOLE AT FRONT
OF HEAT EXCHANGER FOR 15-20 MINUTES BEFORE ATTEMPTING TO
RELIGHT.
LET REMAINING EXCESS OIL BURN OFF BEFORE
CHECKING COMBUSTION OF UNIT.

TO SHUT DOWN: