OPERATING INSTRUCTIONS MANUAL
(Please retain for future reference)
For
F-1000T DUAL FUEL CONSTRUCTION HEATER
CERTIFIED FOR USE IN CANADA AND U.S.A.
As per Standard ANSI Z83.7 2000/
CSA 2.14 2000 Gas Fired Construction Heaters Unvented/Unattended Type.
FLAGRO INDUSTRIES LIMITED
ST. CATHARNIES, ONTARIO
CANADA

Advertisement

Table of Contents
loading

Summary of Contents for Flagro F-1000T

  • Page 1 OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired Construction Heaters Unvented/Unattended Type. FLAGRO INDUSTRIES LIMITED ST. CATHARNIES, ONTARIO...
  • Page 2 GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
  • Page 3: Specifications

    ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these. SPECIFICATIONS Model Number F-1000T Input 1,000,000 btuh Fuel Natural Gas or Propane Inlet Pressure Natural Gas: 7.0” W.C.
  • Page 4: Installation

    INSTALLATION: The installation of this heater for use with natural gas shall conform with local codes or, in the absence of codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 and the Natural Gas and Propane Installation Code, CSA B149.1. The installation of this heater for use with propane tank or cylinder shall conform with Local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and...
  • Page 5 PRESSURES: MAXIMUM INLET PRESSURES: LP: 14.0 IN. WC. NG: 14.0 IN. WC. MINIMUM INLET PRESSURES: LP: 11.0 IN. WC. NG: 7.0 IN. WC. This heater must be supplied by pressures indicated on the approval label. Over pressure may cause controls to fail. DO NOT supply this unit with more than ½...
  • Page 6: Maintenance

    MAINTENANCE: Every construction heater should be inspected before each use, and at least annually by a qualified service person. The hose assembly shall be visually inspected prior to each use of the heater. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation.
  • Page 7: To Shut Down

    F-1000T START UP INSTRUCTIONS: 1. Set fuel selector valve according to gas supply to be used 2. Connect construction heater to gas supply with approved hose assembly. 3. Plug the electrical cord into a 20 amp supply. 4. Open all gas supply valves.
  • Page 8 F-1000T TROUBLESHOOTING ANALYSIS: PROBLEM: HEATER WILL NOT LIGHT Air switch improperly set. POSSIBLE CAUSE: Use centre adjusting screw to set REMEDY: air switch. Turn clockwise to increase sensitivity, turn counter clockwise to decrease sensitivity. Blockage in copper inlet tubes. POSSIBLE CAUSE: Disconnect tubes from air switch.
  • Page 9 Faulty Solenoid. POSSIBLE CAUSE: Ensure solenoid is energized. REMEDY: (use volt meter) Ensure plunger in the solenoid is being activated. (use manometer at test point after solenoid) (use volt meter) Incorrect Gas Supply. POSSIBLE CAUSE: Ensure required gas supply pressures REMEDY: are supplied to the heater.
  • Page 10 PROBLEM: HEATER WILL NOT REMAIN LIT AFTER START UP Faulty flamerod wire. POSSIBLE CAUSE: Check flamerod wire for any damage. REMEDY: Ensure connections are secure. Replace flamerod if necessary.
  • Page 11 F-1000T – PARTS LIST 1 HP MOTOR FAN BLADE REGULATOR (1/2 PSI) S-1000 S-1002 S-1001 PRESSURE ADJUSTMENT FUEL SELECTOR VALVE S.S. FILTER SCREEN CAP FOR S-1002 REG S-1003 FUEL SHUT OFF VALVE S-1002FS S-1002C S-1003A 1 ¼” SOLENOID VALVE BURNER...
  • Page 12 F-1000T – PARTS LIST AIR PROVEN SWITCH IGNITION BOARD WIRING HARNESS S-414 S-415P S-415W THERMOSTAT CLEAR INDICATOR LIGHT REAR SCREEN S-416 S-1020A S-1019 POWER CORD RED INDICATOR LIGHT GREEN INDICATOR LIGHT S-1021 S-1020B S-1020C 8” RUBBER WHEELS AIR SENSING TUBES...
  • Page 13 PARTS LIST FOR F-1000T Part Number Part Description S-1000 1 HP MOTOR S-1001 FAN BLADE S-1002 REGULATOR S-1002FS S.S. FILTER SCREEN S-1003 FUEL SELECTOR VALVE S-1003A FUEL SHUT OFF VALVE S-1004 ASCO SOLENOID VALVE S-1005 BURNER S-406A FLAME ROD S-407A...
  • Page 14 F-1000T WIRING DIAGRAM 2010 CLEAR LIGHT ON/OFF HIGH LIMIT RELAY 120 VOLT FAN MOTOR RED LIGHT GROUND MOMENTARY ON COIL THERMOSTAT AIR SWITCH GREEN LIGHT FLAME ROD GROUND SOLENOID VALVE SPARK PLUG FENWAL IGNITION BOARD (POTTED CONTROL) SOLENOID VALVE FLAGRO INDUSTRIES LIMITED Note: If any of the origional wire as supplied with the appliance must be replaced it must be replaced with type 14g TEW wire or its equivalent.