Flagro FVNP-400RC Operating Instructions Manual

Indirect fired space heaters

Advertisement

OPERATING INSTRUCTIONS MANUAL
(Please retain for future reference)
For
FVNP-400RC INDIRECT FIRED SPACE HEATERS
CERTIFIED FOR USE IN CANADA AND U.S.A.
As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction Heaters / Unattended Type.
Issued: September, 2016
2003325
FLAGRO INDUSTRIES LIMITED
ST. CATHARINES, ONTARIO
CANADA

Advertisement

Table of Contents
loading

Summary of Contents for Flagro FVNP-400RC

  • Page 1 OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVNP-400RC INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction Heaters / Unattended Type. Issued: September, 2016 2003325 FLAGRO INDUSTRIES LIMITED ST.
  • Page 2 GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
  • Page 3: Specifications

    ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these. SPECIFICATIONS Model …………………………………………………….…. FVNP-400RC Input …………………………………………………….…... 390,000 btuh Fuel …………………………………………………………. Propane / Natural Gas Manifold Pressure ………………………………………….
  • Page 4: Installation

    INSTALLATION: The installation of this heater for use with natural gas shall conform with local codes or, in the absence of codes, with the National Fuel Gas Code ANSI Z233.1/NFPA 54 and the Natural Gas and Propane Installation Code, CSA B149.1-00.
  • Page 5 CONNECTING THE CYLINDER If cylinders are used to supply the heater, no cylinders smaller than 100lb capacity shall be used. These cylinders must supply a vapor withdrawal only. All cylinder connections must be made using a wrench to tighten the POL fitting.
  • Page 6 FUEL: This heater is a dual fuel heater and operates on propane & natural gas. The manifold pressures are listed on the approval label. You do not need to change any of the burner components; you just however, make sure the fuel selector valve is in the proper fuel position.
  • Page 7 This heater is design to attach a return ducting system, see information below. OUTLET DUCTING: Hitex heater duct with a minimum temperature handling of 300 deg F. including wire reinforcement to prevent collapsing. Heater is designed for use with 2 x 12” diameter or 1 x 16”ducts equipped with pin lock/Cuff &...
  • Page 8 FV SERIES CONSTRUCTION HEATER – VENTING REQUIREMENTS 1. VERTICAL FLUE TERMINATIONS VERTICAL FLUE RUN HORIZONTAL FLUE RUN - RISE RATIO 1:10 FLUE OUTLET OF HEATER 2. HORIZONTAL FLUE TERMINATIONS FLUE OUTLET OF HEATER EXTERIOR WALL VENT TERMINATION MUST BE A MINIMUM OF 2FT HIGHER THAN ANY POINT WITHIN 10FT.
  • Page 9: Maintenance

    MAINTENANCE: 1. Every construction heater should be inspected before each use, and at least annually by a qualified service person. Incorrect maintenance my result in improper operation of the heater and serious injury could occur. 2. Service and maintenance should only be done by a qualified service person. The hose assemblies shall be visually inspected prior to each use of the heater.
  • Page 10: Start-Up Instructions

    START UP INSTRUCTIONS: Be sure the switch is in the “OFF” position. Ensure electrical cord is grounded and heater is on a level surface. Plug in supply cord to 115v, 15amp outlet. Move switch to “MANUAL” position for manual control. Move switch to “THERMOSTAT”...
  • Page 11: Safe Operation Precautions

    IF HEATER FAILS TO START: Press manual reset button at rear of burner. Check gas pressure supply. Supply and manifold pressure must follow those on rating plate. Ensure proper power supply and extension cord is being used. If heater fails to ignite after 3 attempts, call your supplier for service. SAFE OPERATION PRECAUTIONS: For use with propane or natural gas only.
  • Page 12: Firing Rate

    COMBUSTION AIR ADJUSTMENTS: NOTE: Proper combustion air adjustment must be achieved using a certified combustion analyzer to ensure complete combustion. The air adjustment should be made to achieve 10% CO on natural gas and 12% CO on propane. SETTING THE AIR ADJUSTMENT PLATE A) Regulation of the combustion air flow is made by adjustment of the manual AIR ADJUSTMENT PLATE (1) after loosening the FIXING SCREWS (2 and 3).
  • Page 13 TEMPERATURE FEELER GAUGE ADJUSTMENT (ATTACHED TO FAN SWITCH) The temperature feeler gauge is required to be always touching the heater exchanger. The temperature feeler gauge controls the air flow over the fan switch, which eliminates any unnecessary fan cycling. The temperature feeler gauge can be adjusted for different outside temperatures, by rotating the location of the temperature feeler gauge holes.
  • Page 14: Burner Dimensions

    In extreme cold conditions, cover the holes on the temperature feeler gauge using foil tape. Ensure that the temperature feeler gauge is readjusted for warmer weather conditions. Failure to do so may result in burning out fan switches – not covered under warranty. PRINCIPAL BURNER COMPONENTS 1.
  • Page 15 Model 400 inches 10 5/16 1 3/8 13 11/16 3 3/4 4 1/8 2262 *G1 is for LBT version Gasket thickness is 4 millimeters ELECTRODE AND FLAME PROBE ADJUSTMENTS IMPORTANT: Do not turn the ignition electrode. Leave it as shown in the drawing.
  • Page 16: Field Wiring Diagram

    GAS TRAIN LEGEND GAS SUPPLY & FLOW DIRECTION GAS APPLIANCE PRESSURE OF GAS REGULATOR AS SUPPLY MAIN SHUTOFF MANUAL SAFETY SHUTOFF GAS VALVE VALVE (FIELD SUPPLIED (VS) 24V OR 120V SUPPLIED) OPERATED GAS SUPPLY PRESSURE TEST MAIN GAS VALVE (V1) 24V OR 120V POINT (FIELD SUPPLIED) OPERATED SINGLE STAGE GAS TRAIN PIPE DIAMETER SIZE(S):...
  • Page 17 FACTORY WIRING DIAGRAM NOTE: 1. This burner is approved for use without the motorized air damper. In these instances optional wiring is used 2. The SAFETY SWITCH on the 525 SE CONTROL BOX is equipped with a contact allowing remote sensing of burner lockout. The electrical connection is located on the CONTROL BOX terminal 4 as indicated.
  • Page 18 PARTS LIST FOR FVNP-400RC Part Number Part Description FV-401A 1 HP FAN MOTOR FOR FVO/FVN/FVP (RC UNIT) FV-402RC 16" BC IMPELLER FOR FV-400RC FV-402RCA VENTURI FOR 16" BC IMPELLER FV-403A 16" FLAT FREE WHEEL FV-404 18" POWER CORD FV-405 SS HEAT EXCHANGER...
  • Page 19 FV-433B FEELER GAUGE - SOLID FV-434CB12 FRONT FACE PLATE ( 2 X12" ) FV-434CB16 FRONT FACE PLATE ( 1 X16" ) FV-437 HIGH LIMIT (REAR) FV-438 LIFTING HARNESS FV-446 SIGHT GLASS C/W FIBER GASKET FV-447 SIGHT GLASS WASHER FV-448 MAIN RELAY FV-450SI SMART INDICATOR FV-469...
  • Page 20 G400 LP/NG BURNER - PARTS DIAGRAM...
  • Page 21 RIELLO BURNER G400 - PARTS LIST DIAGRAM PART NUMBER DESCRIPTION FV-20136636-LPNG PLASTIC BURNER COVER C/W LABELS FVNP-3020314 AIR PRESSURE SWITCH FVNP-300162 IGNITION MODULE FVNP-3002307 SUB-BASE FOR IGNITION MODULE FVNP-3006356 MOUNTING FLANGE FVNP-3007288 AIR SWITCH TUBE & CONNECTOR FVNP-3007310 IONIZATION LEAD FVNP-3007293 AIR TUBE COVER PLATE FVNP-3006688...
  • Page 22 FVNP-400RC WIRING DIAGRAM 150F High Limit Thermostat Connection Riello Burner Manual 250F Remote High Limit Toggle 1 HP 1725 RPM Burner Motor Lockout Fan Limit Omron Relay Power Supply Indicator 120 Volt 120 Volt Meter Meter Line Neutral...