Installation
5. Remove the 4 screws retaining the appliance to its
pallet. Snap off the feet attached to the pallet and
discard or recycle.
6. With great care not to cut yourself on the sharp feet,
set the appliance
partially
in mind the need to access the rear of the appliance
to connect the electrical wires.
into the framing keeping
Set-up Gas Supply
The gas supply inlet connection is a 1/2" NPT male line
stub located on the rear left hand side of the appliance.
The unit is supplied with a stainless steel fl ex line to
allow the appliance to be disconnected for service. An
individual shut-off valve (supplied) is required on the
supply line ahead of the fl ex connector.
Use only new black iron or steel pipes, CSST, or copper
tubing if acceptable—check local codes. Note that
in USA, copper tubing must be internally tinned for
protection against sulfur compounds.
Unions in gas lines should be of ground joint type.
The gas supply line must be sized and installed to
provide a supply of gas suffi cient to meet the maximum
demand of the appliance without undue loss of
pressure.
Sealant used must be resistant to the action of all gas
constituents including LP gas. Sealant should be applied
lightly to male threads to ensure excess sealant does
not enter gas lines.
Rear of
appliance
Electrical access/
Gas line stub
Junction box
1/2" male npt
7-3/8"
(188 mm)
(213 mm)
Left side view

Gas Supply

X
8-5/8"
(219 mm)
2-13/16"
(71 mm)
8-3/8"
29